A pour is only as cold as the last few feet of line it travels through - a glycol-jacketed run holds pour temperature the whole way to the tap.
A keg cooler holds product at storage temperature, but the draft line between the walk-in and the tap is where a warm pour usually starts - a long run without its own cooling picks up heat from the room it passes through. A glycol-jacketed trunk line, circulated from the same chiller that serves the walk-in, holds beer at pour temperature for the entire run, which matters most on longer back-bar or multi-tap installs.
Sizing here is less about tonnage and more about matching glycol supply temperature and flow rate to line length and tap count - an undersized pump or a loop that's too warm shows up as foam and inconsistent pours rather than a failed cooler. Most keg-and-draft-line jobs are a good fit for a smaller portable glycol chiller feeding both the walk-in coil and the jacketed trunk line from one unit.
This is a lighter, steadier duty than fermentation or condensing cooling, but it still needs a properly mixed glycol solution rather than plain water, since trunk lines routinely run well below what water can hold without freezing in the chiller's own heat exchanger.
Draft line length and tap count drive load more than keg volume does - a long run to a remote bar or a large tap wall has to hold pour temperature over more linear feet of glycol-jacketed trunk line than a short run with a handful of taps. Walk-in keg cooler holding is a separate, steadier load layered on top.
Most draft systems run a small dedicated glycol chiller rather than sharing a production chiller, since the loop, pump and reservoir are sized specifically for trunk-line length and tap count rather than brewery process tonnage.
| Duty | Leaving Fluid Temp | Load Profile | Typical Glycol Mix |
|---|---|---|---|
| Draft trunk line | 28-34°F | Continuous, line-length driven | 25-30% propylene |
| Walk-in keg cooler | 34-38°F | Continuous, flat | 20-25% propylene |
Ranges are typical starting points, not a substitute for a line-length and tap-count calculation - actual leaving fluid temperature and glycol percentage depend on your trunk-line run and tap wall.