A glycol loop that isn't filtered accumulates scale and debris that show up first as fouled heat exchangers, then as chiller performance loss.
Glycol loops accumulate particulate over time from pipe scale, seal wear, and whatever gets introduced during installation or maintenance, and that debris fouls heat exchangers and erodes control valve performance long before it causes an obvious failure. Inline filtration - bag filters for coarse debris, permanent media filters for finer particulate - keeps the loop clean enough that the chiller's rated capacity actually holds up over years of service, not just at startup.
Fluid management also covers glycol concentration monitoring over time: evaporation, top-offs with plain water, and gradual degradation can all shift the actual mix percentage away from what was originally specified, which quietly changes both freeze protection and heat transfer performance. Periodic testing (a simple refractometer check) catches this before it becomes a freeze-up risk in cold weather.
Filtration and fluid management are inexpensive relative to the cost of a fouled heat exchanger or an unplanned freeze-up, and they're worth specifying as part of a new system rather than added after a problem shows up.
Pipe scale, seal wear or recent installation work
Bag at 25-100 micron, permanent media at 5-25 micron
A refractometer check at startup, then periodically
Replace loaded bags and clean the permanent media
Glycol loops accumulate particulate over time from pipe scale, seal wear, and whatever gets introduced during installation or maintenance, and that debris fouls heat exchangers and erodes control valve performance long before it causes an obvious failure. Inline filtration keeps the loop clean enough that rated capacity actually holds up over years of service, not just at startup.
Fluid management also covers glycol concentration monitoring over time - evaporation, top-offs with plain water, and gradual degradation can all shift the actual mix percentage away from what was originally specified, quietly changing both freeze protection and heat transfer performance.
| Type | Typical Micron Range | Best For |
|---|---|---|
| Bag filter | 25-100 micron | Coarse debris, new installation startup |
| Permanent media filter | 5-25 micron | Finer particulate, long-term loop protection |
Filtration and periodic mix testing are inexpensive relative to the cost of a fouled exchanger or a cold-weather freeze-up.