A plant-wide glycol system is a distribution system first - a tank, supply pumps, a header and return piping - with refrigeration attached to it. Built that way, capacity can be added a module at a time as the plant grows, without replacing the pumps or the tank.
The MA and MW chilling modules are built for exactly that. Each is the refrigeration section of a central chiller on its own frame, with one, two or three circuits, and needs a separate reservoir and pumping system. The MA modules reject heat through a remote air-cooled condenser outdoors, the MW modules to tower or city water. This page lists the 22 modules from 60 to 180 tons.
Five MW-120-CCC modules on one tankBuilt in steps from two modules to five, the example plant still carries 400 tons with any one module down. The tank, pumps and header are sized for the finished plant from day one.
At 50°F rating
Growing a Plant to 400 Tons
Tank, pumps and header sized for the final plant.
Two MW-120-CCC modules: 240 tons.
Two more as the load arrives: 480 tons.
Each added while the others keep the loop running.
A fifth module: 600 tons.
Carries 400 tons with any one module down.
| Part Number | Series | Tons (50°F) | Circuits | Condenser | Shipping Weight | Voltage |
|---|---|---|---|---|---|---|
| MA-60-RC-C | MA Modules | 60 | 1 | Remote Air-Cooled | 1,400 lbs | 230V / 460V / 575V |
| MA-60-RC-CC | MA Modules | 60 | 2 | Remote Air-Cooled | 2,350 lbs | 230V / 460V / 575V |
| MA-70-RC-CC | MA Modules | 70 | 2 | Remote Air-Cooled | 2,500 lbs | 230V / 460V / 575V |
| MA-80-RC-CC | MA Modules | 80 | 2 | Remote Air-Cooled | 2,600 lbs | 230V / 460V / 575V |
| MA-100-RC-CC | MA Modules | 90 | 2 | Remote Air-Cooled | 3,450 lbs | 230V / 460V / 575V |
| MA-90-RC-CCC | MA Modules | 90 | 3 | Remote Air-Cooled | 3,300 lbs | 230V / 460V / 575V |
| MA-105-RC-CCC | MA Modules | 103 | 3 | Remote Air-Cooled | 3,450 lbs | 230V / 460V / 575V |
| MA-120-RC-CC | MA Modules | 120 | 2 | Remote Air-Cooled | 3,700 lbs | 230V / 460V / 575V |
| MA-120-RC-CCC | MA Modules | 120 | 3 | Remote Air-Cooled | 3,600 lbs | 230V / 460V / 575V |
| MA-150-RC-CCC | MA Modules | 135 | 3 | Remote Air-Cooled | 3,900 lbs | 230V / 460V / 575V |
| MA-180-RC-CCC | MA Modules | 180 | 3 | Remote Air-Cooled | 4,200 lbs | 230V / 460V / 575V |
| MW-60-C | MW Modules | 60 | 1 | Water-Cooled | 1,400 lbs | 230V / 460V / 575V |
| MW-60-CC | MW Modules | 60 | 2 | Water-Cooled | 2,350 lbs | 230V / 460V / 575V |
| MW-70-CC | MW Modules | 70 | 2 | Water-Cooled | 2,500 lbs | 230V / 460V / 575V |
| MW-80-CC | MW Modules | 80 | 2 | Water-Cooled | 2,600 lbs | 230V / 460V / 575V |
| MW-90-CCC | MW Modules | 90 | 3 | Water-Cooled | 3,300 lbs | 230V / 460V / 575V |
| MW-100-CC | MW Modules | 100 | 2 | Water-Cooled | 3,450 lbs | 230V / 460V / 575V |
| MW-105-CCC | MW Modules | 103 | 3 | Water-Cooled | 3,450 lbs | 230V / 460V / 575V |
| MW-120-CC | MW Modules | 120 | 2 | Water-Cooled | 3,700 lbs | 230V / 460V / 575V |
| MW-120-CCC | MW Modules | 120 | 3 | Water-Cooled | 3,600 lbs | 230V / 460V / 575V |
| MW-150-CCC | MW Modules | 135 | 3 | Water-Cooled | 3,900 lbs | 230V / 460V / 575V |
| MW-180-CCC | MW Modules | 180 | 3 | Water-Cooled | 4,200 lbs | 230V / 460V / 575V |
Ratings at 50°F leaving water. Every module connects to a separate reservoir and pumping system; MA modules are listed without their remote condensers.
MA and MW chilling modules added to a plant's own tank and pump station, a step at a time, as the load grows past 210 tons.
The mistake that limits a plant-wide system is a header or pump set sized for the first phase. Adding a module is quick; replacing a 4-inch header with an 8-inch one is a shutdown. Size the tank, pumps and main piping for the plant the site expects to become, and leave valved, capped connections for the modules still to come.
MA and MW modules can sit side by side on the same tank. A plant with tower capacity to spare adds MW modules; one without adds MA modules and places their condensers outdoors. Their ratings match closely - the MA-120-RC-CC and MW-120-CC are both 120 tons at 50°F and both ship at 3,700 lbs - so the choice is heat rejection, not capacity.
Three module names run ahead of their ratings: the MA-100-RC-CC is rated 90 tons, and the MA-150-RC-CCC and MW-150-CCC 135 tons at 50°F. The table lists the rated figures.
The other line we supply covers this range as well - see it's add-on chiller modules for plant-wide systems to 300 tons on our sister chiller site.