Once a site has three-phase power, a portable chiller can grow to 5 tons without leaving the single-cabinet format. The CG units on this page carry the same arrangement as the smaller CF series - compressor, condenser, reservoir, process pump and controls together - with a bigger tank, a pump sized at about 2.4 GPM per ton, and a choice of air-cooled or water-cooled condensers.
Four are air-cooled (the CG-2A, CG-3A, CG-4A and CGD-5A) and two water-cooled (the CG-2W and CG-3W). The 2- and 3-ton air-cooled units run on 230V or 460V; the rest add 575V. All six are rated at 50°F leaving water.
Temperature rise the CG pumps assumeBuilt-in pump flow is set for this rise at full load. A mold or plate exchanger that needs a 4°F rise wants a separate circulation loop, not a bigger compressor.
Before you order
Where It Will Stand
Air-cooled units need the room to stay under 95°F with the chiller running.
Allow for the load plus the compressor heat.
Water-cooled units need 60°F city water or 85°F tower water.
And a drain or a return for it.
A three-phase feed at 230V, 460V or 575V.
Check the voltages the model you pick is built for.
| Part Number | Series | Tons (50°F) | Condenser | Process Flow | Reservoir | Voltage | Shipping Weight |
|---|---|---|---|---|---|---|---|
| CG-2A | CG Air-Cooled | 2 | Air-Cooled | 4.8 GPM | 7.5 gal | 230V / 460V | 415 lbs |
| CG-3A | CG Air-Cooled | 2.9 | Air-Cooled | 7.2 GPM | 7.5 gal | 230V / 460V | 600 lbs |
| CG-4A | CG Air-Cooled | 4 | Air-Cooled | 9.6 GPM | 25 gal | 230V / 460V / 575V | 800 lbs |
| CGD-5A | CG Air-Cooled | 4.9 | Air-Cooled | 12 GPM | 25 gal | 230V / 460V / 575V | 800 lbs |
| CG-2W | CG Water-Cooled | 2 | Water-Cooled | 4.8 GPM | 7.5 gal | 230V / 460V / 575V | 445 lbs |
| CG-3W | CG Water-Cooled | 3 | Water-Cooled | 7.2 GPM | 7.5 gal | 230V / 460V / 575V | 470 lbs |
Ratings at 50°F leaving water; air-cooled ratings at 95°F ambient. Flow is the built-in process pump's published flow.
Six CG portables from 2 to 4.9 tons for machine tools, molding presses, jacketed vessels and small cellars on three-phase power.
Machine-tool coolant, a single injection press, a jacketed reactor, a small cellar of fermenters: most three-phase portable duties in this range are one load at one setpoint. The selection is the capacity at that setpoint, the flow the load needs, and where the heat goes.
The pumps are sized for about a 10°F rise at full load - 4.8 GPM on the 2-ton units, 12 GPM on the CGD-5A. A mold or a plate exchanger that needs a 4°F rise at 4 tons needs 24 GPM, more than twice what the CG-4A pump moves. That duty wants a separate circulation loop or a larger unit's pump, not the next compressor size.
Where a portable would sit in a 100°F press hall or a mechanical room with no ventilation, the water-cooled units keep their rating whatever the room temperature, provided the water supply is there. They are also lighter than the air-cooled units of the same size: 470 lbs shipping for the CG-3W against 600 lbs for the CG-3A.
The CG range continues to 29 tons air-cooled and 40 tons water-cooled on the Indoor Packaged Units page of the 5 to 40 ton range.
The other line we supply covers this range as well - see its 2 to 15 ton portable chillers on our sister chiller site.
Call and talk it through with an engineer: 1-805-484-2992