A plant without cooling-tower water still has to put 40 to 100 tons of heat somewhere, and outdoors is the only practical place. This page covers the two ways to do it: move the whole chiller outside, or keep the chiller inside and move only its condenser.
The TTOACS outdoor packages (42.7 to 84.6 tons here) carry condenser, compressors, tank and pumps on one frame and are published at 460V. The TTI air-cooled central chillers (50 to 90 tons) and MA chilling modules (46.4 to 90 tons) stay indoors and connect to a remote air-cooled condenser through refrigerant lines; they are published at 230V, 460V and 575V.
Low ambient limit of a TTOACS packageAn outdoor package runs down to this, but its compressors and controls are serviced in that weather. A remote condenser keeps them in a heated room at the cost of a field line set.
Outdoor or remote
Three Questions
None inside: an outdoor package takes none.
Room to spare: a TTI or MA keeps compressors in reach.
Outdoor packages run to -20°F ambient.
A remote condenser keeps the chiller itself indoors.
Already there: MA modules add to it.
Not yet: a TTI or TTOACS brings its own.
| Part Number | Series | Tons (50°F) | Condenser | Zones | Tank / Pump | Voltage |
|---|---|---|---|---|---|---|
| TTI-50A | TTI Air-Cooled | 50 | Remote Air-Cooled | 2 | 340 gal / 120 GPM | 230V / 460V / 575V |
| TTI-60A | TTI Air-Cooled | 57 | Remote Air-Cooled | 2 | 340 gal / 144 GPM | 230V / 460V / 575V |
| TTI-80A | TTI Air-Cooled | 80 | Remote Air-Cooled | 2 | 1,200 gal / 240 GPM | 230V / 460V / 575V |
| TTI-90A | TTI Air-Cooled | 85.5 | Remote Air-Cooled | 3 | 1,200 gal / 270 GPM | 230V / 460V / 575V |
| TTI-100A | TTI Air-Cooled | 90 | Remote Air-Cooled | 2 | 1,200 gal / 300 GPM | 230V / 460V / 575V |
| MA-50-RC-C | MA Modules | 46.4 | Remote Air-Cooled | 1 | Separate | 230V / 460V / 575V |
| MA-50-RC-CC | MA Modules | 50 | Remote Air-Cooled | 2 | Separate | 230V / 460V / 575V |
| MA-60-RC-C | MA Modules | 60 | Remote Air-Cooled | 1 | Separate | 230V / 460V / 575V |
| MA-60-RC-CC | MA Modules | 60 | Remote Air-Cooled | 2 | Separate | 230V / 460V / 575V |
| MA-70-RC-CC | MA Modules | 70 | Remote Air-Cooled | 2 | Separate | 230V / 460V / 575V |
| MA-80-RC-CC | MA Modules | 80 | Remote Air-Cooled | 2 | Separate | 230V / 460V / 575V |
| MA-100-RC-CC | MA Modules | 90 | Remote Air-Cooled | 2 | Separate | 230V / 460V / 575V |
| MA-90-RC-CCC | MA Modules | 90 | Remote Air-Cooled | 3 | Separate | 230V / 460V / 575V |
| TTOACS-50S-CG-1P | TTOACS | 42.7 | Air-Cooled | 1 | 150 gal / 120 GPM | 460V |
| TTOACS-50D-MZC-2P | TTOACS | 48.4 | Air-Cooled | 2 | 200 gal / 120 GPM | 460V |
| TTOACS-60S-CG-1P | TTOACS | 55.1 | Air-Cooled | 1 | 300 gal / 144 GPM | 460V |
| TTOACS-60D-MZC-2P | TTOACS | 57.4 | Air-Cooled | 2 | 400 gal / 144 GPM | 460V |
| TTOACS-80D-MZC-2P | TTOACS | 75.8 | Air-Cooled | 2 | 400 gal / 192 GPM | 460V |
| TTOACS-100D-MZC-2P | TTOACS | 84.6 | Air-Cooled | 2 | 400 gal / 240 GPM | 460V |
Ratings at 50°F leaving water. TTI air-cooled and MA units are listed without their remote condensers; MA modules connect to a separate reservoir and pumping system.
Heat rejected outdoors: complete TTOACS packages on a pad, or TTI chillers and MA modules indoors with their condensers outside.
The outdoor package is the simplest installation - a pad, power, and two insulated lines to the building - and the right answer where mechanical-room space is short. Its compressors and controls live outdoors, so service happens in the weather. The remote-condenser arrangement keeps them in a heated room, at the cost of a refrigerant line set that a refrigeration contractor installs and charges.
The model name is a size class, and in this range several ratings sit below it: the TTOACS-100D-MZC-2P is rated 84.6 tons, the TTI-100A 90 tons and the MA-100-RC-CC 90 tons at 50°F. Always select from the rated figure.
An outdoor package's own piping and tank sit in winter air, so its loop runs glycol at every setpoint. A remote-condenser system keeps the process loop indoors; only the refrigerant side goes outside, and the loop needs glycol only where the process setpoint or the building's own piping calls for it.
The other line we supply covers this range as well - see its outdoor air-cooled central chillers, 5 to 210 tons on our sister chiller site.