Replacement unit for the AAON LF Series

LF Series

AAON's small air-cooled chiller: the LF Series, 4 to 55 nominal tons on R-410A, now listed by AAON as obsolete.

PRODUCT TYPE CAPACITY MODELS
Air-Cooled Chiller Packaged, Air-Cooled 4 to 55 nominal tons 19

Specifications


Configuration & Size

Capacity:
4 to 55 nominal tons
Models:
19 part numbers
Refrigerant:
R-410A
Cabinets:
A, B, C and D
Status:
Obsolete (AAON)

Construction

  • R-410A scroll compressors
  • Microchannel condenser coils
  • Brazed plate or shell and tube evaporator
  • Optional factory pumping package
  • 2 in double-wall foam panel cabinet

Ratings

  • Nominal tons by unit size
  • Rating point not stated
  • Low ambient to 0°F
  • Maximum pressure 125 psi

Specifications sourced from AAON's published LF Series brochure and installation manual (aaon.com), October 2026. AAON is a trademark of AAON, Inc.; referenced here for cross-reference only. Sizes are AAON's nominal tons. Confirm against the unit nameplate before ordering.

LF Series, 4 to 55 Nominal Tons

Nineteen Sizes in Four Cabinets

Four cabinets. A holds the 4, 5, 7 and 9-ton sizes; B the 8, 10, 11 and 13; C the 14, 15, 17, 22 and 24; D the 21, 26, 31, 42, 48 and 55.

Compressor choices. Staged, tandem or 10 to 100% variable capacity R-410A scroll compressors.

Pumps in the cabinet. A factory pumping package with pump, butterfly valves, strainers and ball valves was an option.

Water connections. Grooved schedule 40 pipe: 1-1/2 inch on the A cabinet, 2 inch on B and C, 3 inch on D, at up to 125 psi.



a sanitation worker with a clipboard in a tiled washdown room

Scroll compressors, microchannel condenser coils and a brazed plate or shell and tube evaporator, with optional pumps.

Request a Quote

LF Series Applications

Chilled water
Chilled water
Brewery glycol
Brewery glycol
Process loops
Process loops
Outdoor pads
Outdoor pads

schematic of the LF series circuit, showing where the process fluid and the condenser heat go

An Obsolete Line Is a Replacement Question

AAON still supports the LF, but it no longer builds it. When a compressor or a microchannel coil fails on an older unit, compare the repair against a new chiller sized for the loop as it runs today. The glycol chiller sizing guide works the load from flow and temperature rise.

Every part-number page below names the Temptek unit we supply in its place, sized from AAON's nominal tons on Temptek's 0.80 multiplier at 40°F.
Call and talk it through with an engineer: 1-805-484-2992

AAON LF Series: Sizes, Cabinets and What We Supply

No, it follows the cabinet letter, and the cabinets do not run in strict tonnage order. The 9-ton size sits in the A cabinet with a 1-1/2 inch grooved stub, while the smaller 8-ton LF-008 is a B cabinet piped at 2 inch. Higher up, the 21-ton size is a D cabinet at 3 inch, yet the 22 and 24-ton sizes are C cabinets at 2 inch. Plan the adapter spools from tonnage alone and the fitter can arrive with the wrong size. Read the cabinet letter from the nameplate or feature string, measure the stub, and remember the old unit was limited to 125 psi on the water side.

Because AAON publishes no rating point, its 17 tons are treated as a 44°F comfort figure, and at Temptek's 0.80 factor for 40°F that asks for 21.25 tons of 50°F rating. The TTOACS-25S-CG-1P, rated 24.2 tons at 50°F, clears that by about 3 tons. Worked the other way, 24.2 x 0.80 gives roughly 19.4 tons at 40°F, a little over 2 tons above the old badge. The mistake to avoid is ordering 17 tons at 50°F to match the label: at 40°F that unit makes about 13.6 tons, well short of the duty the label implies. With no published rating point to lean on, the pick is confirmed at your actual set point before the quote is made firm.

We supply the Temptek CGD-7.5A air-cooled portable, rated 7.2 tons, in place of the LF-004. On the 0.80 multiplier the 4 nominal tons call for 5.0 tons of 50°F rating, so the CGD-7.5A has about 2.2 tons in hand, or close to 5.8 tons at 40°F. The change worth planning is siting: the LF-004 is an A-cabinet packaged unit that AAON published for mechanical cooling down to 0°F on flooded condenser control, and a portable is a different format. Tell us where the old unit sits and the coldest winter air at that spot.

Everything in that package leaves with the old cabinet: the pump, its butterfly and ball valves and the strainers, so the loop needs a new home for each. Start with the duty the old pump was doing. For water, flow equals load divided by 500 times the temperature rise, so a 31-ton LF-031, carrying 372,000 BTU/hr with a 10°F rise, moves about 74 GPM; a glycol loop needs somewhat more. Record the pressure the pump made at that flow, then decide with us whether a pump package on the replacement takes it over or a separate pump station is the better fit. A loop that quietly lost its strainer in the swap tends to show it months later as a fouled evaporator.