1-805-484-2992

Quotes - Sizing - Sales

Multistack ASC Air-Cooled Chiller Models

The Multistack ASC stand-alone line, 19 to 198 nominal tons

Contact us

Multistack's Packaged Air-Cooled Chiller

The Multistack ASC stand-alone line, 26 part numbers, from 19 to 198 nominal tons. Each one is listed with its published figures and the unit we supply in its place.

Multistack is best known for modular chillers, banks of small modules joined on common headers. The ASC is its stand-alone packaged line: one air-cooled chiller of 20 to 195 tons with two to six scroll compressors, dual refrigeration circuits on R-410A and a brazed plate evaporator. The catalog publishes a total nominal tonnage, weights, dimensions and the electrical ratings at four voltages for all 26 models, which makes an ASC nameplate easy to look up.

  • Twenty-six models, ASC020X to ASC195X.
  • Total nominal capacity from 19 to 198 tons.
  • Two to six scroll compressors on dual circuits.
  • R-410A with a brazed plate evaporator.
  • Frames 77 to 343 inches long.
  • Low ambient option to -20°F.
26
ASC stand-alone part numbers listed
19 to 198 tons
total nominal tons in the ASC catalog
208 to 575 V
listed supply range, three-phase
550/590
AHRI standard the guide specification cites
Replacement unit for the Multistack ASC Series

ASC Series:

Air-Cooled Stand-Alone

  • 26 part numbers
  • 19 to 198 nominal tons
  • Dual refrigeration circuits

Reading an ASC Model Number

ASC, three digits, X. ASC is air-cooled stand-alone. The digits are close to the nominal tons, but not exact: an ASC060X totals 57 nominal tons and an ASC195X totals 198.

Pairs ending in 0 and 1 or 5 and 6. Several sizes come as a pair, such as the ASC020X and ASC021X. The catalog lists the 020X with two compressors and the 021X with four of about the same total tonnage: more, smaller compressors for finer capacity steps.

The voltage is not in the model. Each model is listed at 208, 230, 460 and 575 V, three-phase 60 Hz, with its own minimum circuit ampacity, so read the voltage off the nameplate. The tonnage and capacity guide explains nominal against working capacity.

Replacing a Multistack ASC

We do not sell Multistack equipment. We supply new Temptek process chillers, and every ASC part-number page names the Temptek unit we would put in its place. Multistack's guide specification rates the ASC under AHRI 550/590, which means 44°F leaving water and 95°F ambient; Temptek rates at 50°F and 95°F. A chiller makes less at 44°F than at 50°F, so the Multistack tons are matched on Temptek's published 40°F multiplier of 0.80: the nominal figure divided by 0.80, which leaves the pick some margin.

From the ASC165X up, the divided figure passes the largest single Temptek outdoor chiller, and those pages point to the add-on module range on our sister site. Send the model, serial, voltage, set point and glycol mix.
Call and talk it through with an engineer: 1-805-484-2992

Specifications sourced from Multistack's published ASC air-cooled stand-alone chiller product catalog (multistack.com), October 2026. Multistack is a trademark of its owner; referenced here for cross-reference only. Capacities are the catalog's total nominal tons. Confirm against the unit nameplate before ordering.

Before You Order

refrigerant cylinders and gauges for a chiller refrigerant change

REPLACE • REFRIGERANT

Refrigerant Phase-Out

Older units in the field may still run R-22 or R-410A. What the refrigerant change means for service, retrofit and replacement.

+ Learn More
chiller swap-out checklist on a clipboard in a plant room

REPLACE • INSTALL

Swap-Out Checklist

Rigging, electrical, piping and start-up items to settle before the old chiller comes out of service.

+ Learn More
aging outdoor chiller showing wear on a concrete pad

REPLACE • CONDITION

Signs You Need a New Chiller

Short cycling, rising amps, a tank that will not pull down: the symptoms that say the old unit is near the end.

+ Learn More

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales