1-805-484-2992

Quotes - Sizing - Sales

CGAM030

Trane
Product Type Capacity Refrigerant
Air-Cooled Scroll Chiller Air-Cooled 30 Tons nominal R-454B

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n CGAM030 as shown on this page.

Replacement chiller for the Trane CGAM030

Description

The Trane CGAM030 is the 30-ton nominal size of the CGAM air-cooled scroll chiller, with 2 scroll compressors on one refrigerant circuit and 3 condenser fans. Trane lists an evaporator flow range of 33.1 to 100 GPM and capacity steps of 50-100 percent, on R-454B. The catalog gives the size as nominal tons; the rated capacity is on the nameplate and in Trane's selection data. Replacement: we supply the Temptek TTOACS-40S-CG-1P, an outdoor air-cooled packaged chiller rated 38.4 tons at 50°F, against the 30 tons Trane publishes for this unit at its nominal size (AHRI conditions, 44°F leaving water). Temptek rates at 50°F, so the 44°F figure is matched on Temptek's published 40°F capacity multiplier of 0.80, which leaves the pick some margin; we confirm it at your set point.

Product Overview

Part Number:
CGAM030
Manufacturer:
Trane
Series:
CGAM Series
Replacement Unit:
Temptek TTOACS-40S-CG-1P

Published Capacity

Nominal Size:
30 tons
Rating Basis:
AHRI 550/590; rated capacity from Trane selection data
Standard Leaving Fluid:
40 to 65°F
Low-Temperature Process Option:
10 to 40°F with glycol
Ambient Range:
0°F (wide) or 32°F (high) to 125°F; -20°F extreme-low option

Configuration & Specifications

Compressors:
2 scroll
Compressor Tons per Circuit:
15+15
Refrigerant Circuits:
1
Capacity Steps:
50-100 %
Refrigerant:
R-454B
Refrigerant Charge per Circuit:
48 lb
Condenser Fans:
3 x 28.8 in, 1.3 HP
Controller:
Symbio 800

Evaporator & Pump Package

Evaporator Water Storage:
2.2 gallons
Min Flow (LWT 42°F and above):
33.1 GPM
Max Flow:
100 GPM
Max Water Pressure:
150 psig
Optional Pump Package:
5 HP, 71.1 ft available head
Optional Buffer Tank:
140 gallons

Electrical

Voltages Offered:
200, 230, 380, 460 or 575 V / 60 Hz / 3 phase

Connections

Water Connection:
2.5 in

Dimensions & Weight

Length:
149.8 in
Width:
50.4 in
Height:
84.7 in
Shipping Weight (base unit):
2,945 lb
Operating Weight (base unit):
2,979 lb

Specifications sourced from Trane's published product catalogs CG-PRC017AA-EN and AC-PRC002K-EN (tranetechnologies.com), October 2026. Trane, CGAM, Ascend and Symbio are trademarks of Trane Technologies; referenced here for cross-reference only. Sizes are Trane's nominal tons; rated performance comes from Trane's selection data. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales