1-805-484-2992

Quotes - Sizing - Sales

CGAM130

Trane
Product Type Capacity Refrigerant
Air-Cooled Scroll Chiller Air-Cooled 130 Tons nominal R-454B

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n CGAM130 as shown on this page.

Replacement chiller for the Trane CGAM130

Description

The Trane CGAM130 is the 130-ton nominal size of the CGAM air-cooled scroll chiller, with 6 scroll compressors on two refrigerant circuits and 10 condenser fans. Trane lists an evaporator flow range of 146.9 to 440 GPM and capacity steps of 15-31-46-62-81-100 percent, on R-454B. The catalog gives the size as nominal tons; the rated capacity is on the nameplate and in Trane's selection data. Replacement: we supply the Temptek TTOACS-190D-MZC-2P, an outdoor air-cooled packaged chiller rated 170.1 tons at 50°F, against the 130 tons Trane publishes for this unit at its nominal size (AHRI conditions, 44°F leaving water). Temptek rates at 50°F, so the 44°F figure is matched on Temptek's published 40°F capacity multiplier of 0.80, which leaves the pick some margin; we confirm it at your set point.

Product Overview

Part Number:
CGAM130
Manufacturer:
Trane
Series:
CGAM Series
Replacement Unit:
Temptek TTOACS-190D-MZC-2P

Published Capacity

Nominal Size:
130 tons
Rating Basis:
AHRI 550/590; rated capacity from Trane selection data
Standard Leaving Fluid:
40 to 65°F
Low-Temperature Process Option:
10 to 40°F with glycol
Ambient Range:
0°F (wide) or 32°F (high) to 125°F; -20°F extreme-low option

Configuration & Specifications

Compressors:
6 scroll
Compressor Tons per Circuit:
20+20+25
Refrigerant Circuits:
2
Capacity Steps:
15-31-46-62-81-100 %
Refrigerant:
R-454B
Refrigerant Charge per Circuit:
97 lb
Condenser Fans:
10 x 28.8 in, 1.3 HP
Controller:
Symbio 800

Evaporator & Pump Package

Evaporator Water Storage:
11.5 gallons
Min Flow (LWT 42°F and above):
146.9 GPM
Max Flow:
440 GPM
Max Water Pressure:
150 psig
Optional Pump Package:
15 HP, 62.2 ft available head
Optional Buffer Tank:
195 gallons

Electrical

Voltages Offered:
200, 230, 380, 460 or 575 V / 60 Hz / 3 phase

Connections

Water Connection:
4 in

Dimensions & Weight

Length:
201.9 in
Width:
88.2 in
Height:
92.5 in
Shipping Weight (base unit):
7,753 lb
Operating Weight (base unit):
7,900 lb

Specifications sourced from Trane's published product catalogs CG-PRC017AA-EN and AC-PRC002K-EN (tranetechnologies.com), October 2026. Trane, CGAM, Ascend and Symbio are trademarks of Trane Technologies; referenced here for cross-reference only. Sizes are Trane's nominal tons; rated performance comes from Trane's selection data. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales