Replacement unit for the Carrier AquaSnap 30RC 067-252 Series

AquaSnap 30RC 067-252 Series

The larger AquaSnap 30RC: 67 to 252 nominal tons on R-32, in standard and compact tiers.

PRODUCT TYPE CAPACITY MODELS
Air-Cooled Scroll Chiller Packaged, Air-Cooled 67 to 252 nominal tons 24

Specifications


Configuration & Size

Capacity:
67 to 252 nominal tons
Models:
24 part numbers
Refrigerant:
R-32
Circuits:
2
Tiers:
Standard and compact

Construction

  • Four to six scroll compressors
  • Two refrigerant circuits
  • Standard or compact frame
  • Fixed or variable speed condenser fans
  • R-32 with electronic expansion valves

Ratings

  • Nominal capacity, AHRI 550/590
  • Brine application below 38°F
  • Frames 105 to 341 in long
  • 88 in wide, 99 in high

Specifications sourced from Carrier's published AquaSnap 30RC product data, Forms 30RC-100PD and 30RC-3PD (carrier.com), October 2026. Carrier and AquaSnap are trademarks of Carrier; referenced here for cross-reference only. Sizes are Carrier's nominal tons; ratings come from Carrier's selection program. Confirm against the unit nameplate before ordering.

AquaSnap 30RC, 67 to 252 Nominal Tons

Two Tiers on One Width

Twenty-four models. Fourteen standard sizes from 067 to 252 and ten compact models, marked C, from 092 C to 252 C.

Compact means shorter. A 30RC152 is 199 inches long; the compact 30RC152 C is 152. Every size is 88 inches wide and 99 high.

Four to six compressors. Scroll compressors of 23.7 to 61.2 hp each, split across two circuits.

Brine applications. Carrier treats leaving temperatures below 38°F as a brine application, ordered with an H in model position 11.



a technician in a cleanroom gown holding a water sample bottle to the light

Four to six scroll compressors on two R-32 circuits, on a standard or compact frame.

Request a Quote

AquaSnap 30RC 067-252 Series Applications

Plant chilled water
Plant chilled water
Data centers
Data centers
Plant-wide molding
Plant-wide molding
Outdoor pads
Outdoor pads

schematic of the AquaSnap 30RC 067-252 series circuit, showing where the process fluid and the condenser heat go

The Largest Sizes Leave Single-Chiller Range

Divided by 0.80, the 30RC from the 152-ton size up calls for more than any single Temptek outdoor chiller makes. Those pages point to the add-on module range on our sister site, paired to the load. Thermal Care sells the Carrier 30RC scroll chiller, 60 to 250 tons, as its 30 Series, so a Thermal Care 30RC nameplate is looked up here. The glycol chiller sizing guide works the load before anyone picks a size.

Every part-number page below names the Temptek unit we supply in its place, sized from Carrier's nominal tons on Temptek's 0.80 multiplier at 40°F, or points to the add-on module range where the size is past a single chiller.
Call and talk it through with an engineer: 1-805-484-2992

Carrier 30RC 067 to 252: Replacement Questions

Divided by Temptek's 0.80 multiplier, the 132-ton unit needs 165 tons of 50°F rating and the 152-ton unit needs 190, which is past any single Temptek outdoor chiller. The 30RC132 is matched to the TTOACS-190D-MZC-2P at 170.1 tons, about 5 tons over the requirement, and from the 152 up we supply add-on chiller modules paired to the load. The tightest single-unit match sits at the bottom of the range: the 30RC067 needs 83.75 tons and the TTOACS-100D-MZC-2P makes 84.6, under 1 ton spare. That one gets checked at your set point and summer ambient before it is quoted firm.

To roughly a fifth of its capacity, judged by compressor horsepower. The 30RC112 carries three 29.6 hp scrolls on circuit A and two of 35.2 hp on circuit B, 159.2 hp in all, so one 29.6 hp compressor is about 19 percent of the total, something near 21 tons of the nominal 112. Horsepower share is only a guide to capacity share, but it marks the old unit's lowest steady step. If the plant's night or weekend load sits below that, the existing chiller has most likely been cycling its smallest compressor on and off, and the replacement should be chosen with that light load in mind as well as the peak.

Not as built: Carrier orders any duty under 38°F leaving as a brine application, marked with an H in position 11, so a nameplate without it was set up for 38°F and warmer. A colder loop is a new duty, not a like-for-like swap. Size it from the set point, because the AHRI 550/590 nominal tons overstate what any chiller delivers in the 20s, and send the glycol type and percentage with it.

Length first, since every 30RC shares an 88-inch width and 99-inch height but frames run from 105 to 341 inches long. The tier letter in position 10 changes that sharply: a standard 30RC152 takes 199 inches of pad and the compact 30RC152 C only 152, a 47-inch difference on the same nominal size. A C on the nameplate may mean the site had no room for the longer frame, so treat pad length as the constraint from the start. Sizes that go to add-on modules get a different layout altogether, so send the pad dimensions, clearances and where the chilled-water pipes come up.