1-805-484-2992

Quotes - Sizing - Sales

EZWC-60-B

Cold Shot
Product Type Capacity Refrigerant
Portable Chiller Air-Cooled Portable 5 Tons @ 50°F R-410A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n EZWC-60-B as shown on this page.

Replacement chiller for the Cold Shot EZWC-60-B

Description

The Cold Shot EZWC-60-B is an air-cooled portable chiller with its pump and tank on board, from the EZ Chiller line. Cold Shot publishes it at 60,000 Btu/h, 5 tons, at 50°F leaving fluid and 95°F ambient. Its stainless centrifugal process pump is listed at 1 hp, 30 GPM at 30 PSI. Cold Shot lists it for 208-230 V three-phase power, with 1 in PVC MNPT IN / OUT process connections. The EZ page adds a hermetic scroll compressor on R-410A, a 25-gallon tank, 24.7 A minimum circuit ampacity and a 40 A MOCP; it is rated for indoor use only, at 44 to 70°F leaving fluid. Replacement: we supply the Temptek CGD-7.5A, an air-cooled portable chiller rated 7.2 tons at 50°F, against the 5 tons Cold Shot publishes for this unit at 50°F leaving fluid and 95°F ambient. Both makers rate at 50°F leaving fluid, so the comparison is like for like.

Product Overview

Part Number:
EZWC-60-B
Manufacturer:
Cold Shot
Replacement Unit:
Temptek CGD-7.5A

Published Capacity

Cooling Capacity:
60,000 Btu/h (5 tons)
Rating Basis:
50°F leaving fluid, 95°F ambient (±5%)
Leaving Fluid Range:
44 to 70°F

Configuration & Specifications

Compressor:
Hermetic Scroll
Refrigerant:
R-410A
Condenser:
Air-Cooled
Style:
Portable
Pump and Tank:
Pump and tank on board
Condenser Fans / Airflow:
1 fan, 2300 CFM
Condenser Coil:
Aluminum fins on copper coil, or aluminum microchannel
Evaporator:
Stainless steel, copper brazed
Installation:
Indoor use only

Pump & Reservoir

  • Process Pump: 1 hp
  • Pump Flow: 30 GPM at 30 PSI
  • Tank: 25 gallons

Electrical

  • Voltage Options: 208-230V three-phase
  • Frequency: 60 Hz
  • Minimum Circuit Ampacity: 24.7 A
  • Maximum Overcurrent Protection: 40 A

Connections

Process Connections:
1 in PVC MNPT IN / OUT

Dimensions & Weight

Dimensions (L x W x H):
72 x 47 x 34 in
Weight:
395 lbs

Specifications sourced from Cold Shot Chillers' published Chiller Specifications page, per-size chiller pages and EZ Chiller page (waterchillers.com), September 2026. Cold Shot Chillers, EZ Chiller and Guardian are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales