1-805-484-2992

Quotes - Sizing - Sales

ES72D-ZD

Drake
Product Type Capacity Refrigerant
Split-System Chiller Split System 7.9 Tons @ 55°F R407C or R404A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n ES72D-ZD as shown on this page.

Replacement chiller for the Drake ES72D-ZD

Description

The Drake ES72D-ZD is an 8 hp dual-circuit digital scroll split-system air-cooled chiller, from the ES / EST Split-System Scroll line. Drake publishes a capacity table for it rather than a single rating: 7.9 tons at 55°F leaving fluid and 95°F ambient on R407C, at an EER of 10.6. The same column runs from 5.1 tons at 35°F to 9.6 tons at 65°F. It is offered on R407C for a 25°F to 55°F suction range and R404A for a -10°F to 45°F suction range. Replacement: we supply the Temptek CGD-10A-RC, an indoor chiller with a remote air-cooled condenser rated 9.8 tons at 50°F, against the 7.9 tons Drake publishes for this unit at 55°F leaving fluid and 95°F ambient on R407C. Drake's table has no 50°F row for this unit, so its 55°F figure is used; a chiller makes at least as much at a warmer set point, so the pick keeps a margin at 50°F.

Product Overview

Part Number:
ES72D-ZD
Manufacturer:
Drake
Replacement Unit:
Temptek CGD-10A-RC

Published Capacity

Cooling Capacity:
7.9 tons at 55°F leaving fluid
Rating Point Used:
55°F leaving fluid, 95°F ambient, R407C
Capacity at 35°F Leaving Fluid:
5.1 tons
Capacity at 45°F Leaving Fluid:
6.4 tons
Capacity at 65°F Leaving Fluid:
9.6 tons
R404A Low-Temperature Range:
2.7 tons at 0°F to 8.2 tons at 55°F
R407C Suction Range:
25°F to 55°F
R404A Suction Range:
-10°F to 45°F

Configuration & Specifications

Horsepower:
8 HP
Compressor:
Digital Scroll
Circuits:
Dual
Condenser:
Remote Air-Cooled (split system)
Refrigerant:
R407C or R404A
Condenser Section:
CS72D

Electrical

Voltage Options:
208-230 V three-phase / 460 V three-phase / 575 V three-phase
Frequency:
60 Hz

Connections

Process Connections:
1-1/4 in F-NPT

Dimensions & Weight

Evaporator Section (L x W x H):
65 x 30 x 39 in
Evaporator Section Weight:
900 lbs

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales