Drake Chiller Models

Nine Drake lines, from a 1.5 hp Value Line to a 200 hp screw

Contact us

Packaged, Water-Cooled and Split Systems

Nine Drake lines, 330 part numbers, from a 1.5 hp Value Line unit to a 200 hp screw chiller. Each one is listed with its published capacity table and the unit we supply in its place.

Drake Refrigeration builds in Bensalem, Pennsylvania, and names its chillers by horsepower rather than tons. The range comes in three arrangements: packaged air-cooled units (PAC, and PACT with a tank), packaged water-cooled units (PWC and PWCT), and split systems (ES and EST) with the compressor indoors and the condenser outside. Each is built on scroll, digital scroll, tandem scroll, semi-hermetic or screw compressors, and most are offered on R407C for process water and R404A for low-temperature glycol. Drake does not publish one capacity per model; every spec sheet carries a table from about 35 to 70°F leaving fluid, and down to 0°F on R404A. The figures on these pages are Drake's own.

  • PAC and PACT scroll packaged air-cooled units run 1.5 to 120 hp, single, dual, multi or tandem circuit.
  • PAC semi-hermetic units run 10 to 100 hp; PAC screw units 80 to 200 hp.
  • Value Line VPACT units are 1.5 to 10 hp packaged chillers with a tank.
  • PWC and PWCT scroll water-cooled units run 1.5 to 120 hp.
  • PWC semi-hermetic units run 10 to 100 hp; PWC screw units 80 to 200 hp.
  • ES and EST split systems run 1.5 to 120 hp on scroll compressors.
  • ES semi-hermetic split systems run 10 to 100 hp.
  • R404A versions reach -10°F suction for low-temperature glycol.
330
Drake part numbers in nine lines
1.5 to 200 hp
Value Line unit up to screw chiller
0°F
low end of Drake's R404A capacity tables
25 to 100%
listed for the dual-circuit screw units
Replacement unit for the Drake Value Line Series

Value Line Series:

Packaged, Air-Cooled, Tank

  • 9 part numbers
  • 1.5 to 10 HP
  • Microprocessor control
Replacement unit for the Drake PAC / PACT Scroll Series

PAC / PACT Scroll Series:

Packaged, Air-Cooled, Scroll

  • 84 part numbers
  • 1.5 to 120 HP
  • PACT models with a tank
Replacement unit for the Drake PAC Semi-Hermetic Series

PAC Semi-Hermetic Series:

Packaged, Semi-Hermetic

  • 21 part numbers
  • 10 to 100 HP
  • Low-temperature R404A
Replacement unit for the Drake PAC Screw Series

PAC Screw Series:

Packaged, Air-Cooled Screw

  • 7 part numbers
  • 80 to 200 HP
  • Dual circuit, 25 to 100%
Replacement unit for the Drake PWC / PWCT Scroll Series

PWC / PWCT Scroll Series:

Packaged, Water-Cooled, Scroll

  • 79 part numbers
  • 1.5 to 120 HP
  • PWCT models with a tank
Replacement unit for the Drake PWC Semi-Hermetic Series

PWC Semi-Hermetic Series:

Water-Cooled, Semi-Hermetic

  • 21 part numbers
  • 10 to 100 HP
  • Low-temperature R404A
Replacement unit for the Drake PWC Screw Series

PWC Screw Series:

Water-Cooled Screw

  • 7 part numbers
  • 80 to 200 HP
  • Dual circuit, 25 to 100%
Replacement unit for the Drake ES / EST Split-System Scroll Series

ES / EST Split-System Scroll Series:

Split System, Scroll

  • 79 part numbers
  • 1.5 to 120 HP
  • CS condenser section outdoors
Replacement unit for the Drake ES Split-System Semi-Hermetic Series

ES Split-System Semi-Hermetic Series:

Split System, Semi-Hermetic

  • 23 part numbers
  • 10 to 100 HP
  • Low-temperature R404A

Reading a Drake Part Number

The letters are the arrangement. PAC is packaged air-cooled and PACT the same unit with a tank; PWC and PWCT are packaged water-cooled; ES and EST are split systems, with a separate CS condenser section outdoors. VPACT is the Value Line.

The number is roughly thousands of Btu/h of nominal size, and the next letter is the circuit count. S is single circuit, D dual, M multi-circuit and Q tandem. A PACT96D is a 10 hp dual-circuit unit with a tank; a PAC1200D-T a 120 hp dual-circuit screw.

The suffix is the compressor. No suffix or -Z is a Copeland scroll, -ZD a digital scroll, -S semi-hermetic and -T screw. The full ordering number adds a refrigerant digit (3 for R407C, 6 for R404A) and a voltage code (S2 208-230/1, T3 208-230/3, T4 460/3, T5 575/3): PACT96D3-T4-Z is the PACT96D on R407C at 460 V.

Replacing a Drake Chiller

We do not sell Drake equipment. We supply new Temptek chillers, and every Drake part-number page names the Temptek unit we would put in its place, in the same condenser arrangement and sized to cover Drake's published capacity. Drake publishes a capacity table on every spec sheet, leaving fluid temperature against ambient or condenser temperature, rather then one rating. Each part-number page names the Temptek unit we supply in its place, matched at 50°F leaving fluid and 95°F ambient, the point Temptek rates at. Where the table has no 50°F row, the next row up is used, which keeps the pick on the safe side; where a water-cooled table is by condensing temperature, the page says which column was used. A packaged air-cooled Drake maps to a Temptek CG portable or TTI central chiller, a water-cooled one to a water-cooled CG or TTI, and a split system to a Temptek CG-ARC or MA unit with a remote condenser.

Low-temperature duty needs a conversation, not a lookup. Drake's R404A tables run down to 0°F; the Temptek units named here are matched at 50°F, and a glycol process at 20°F makes far less. The two largest screw units, above 180 tons, point to the add-on module range on our sister site. Before quoting we ask for the full nameplate model number (it carries the refrigerant and voltage), the set point, the glycol mix and the ambient or condenser water conditions.
Call and talk it through with an engineer: 1-805-484-2992

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

Before You Order

refrigerant cylinders and gauges for a chiller refrigerant change

REPLACE • REFRIGERANT

Refrigerant Phase-Out

Older units in the field may still run R-22 or R-410A. What the refrigerant change means for service, retrofit and replacement.

+ Learn More
chiller swap-out checklist on a clipboard in a plant room

REPLACE • INSTALL

Swap-Out Checklist

Rigging, electrical, piping and start-up items to settle before the old chiller comes out of service.

+ Learn More
aging outdoor chiller showing wear on a concrete pad

REPLACE • CONDITION

Signs You Need a New Chiller

Short cycling, rising amps, a tank that will not pull down: the symptoms that say the old unit is near the end.

+ Learn More

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales