1-805-484-2992

Quotes - Sizing - Sales

ES800D

Drake
Product Type Capacity Refrigerant
Semi-Hermetic Split Chiller Split System 72.4 Tons @ 55°F R407C or R404A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n ES800D as shown on this page.

Replacement chiller for the Drake ES800D

Description

The Drake ES800D is an 80 hp dual-circuit semi-hermetic split-system air-cooled chiller, from the ES Split-System Semi-Hermetic line. Drake publishes a capacity table for it rather than a single rating: 72.4 tons at 55°F leaving fluid and 95°F ambient on R407C, at an EER of 9.9. The same column runs from 32.9 tons at 20°F to 86.6 tons at 65°F. It is offered on R407C for a 10°F to 55°F suction range and R404A for a -10°F to 45°F suction range. Replacement: we supply the Temptek MA-80-RC-CC, an air-cooled chilling module with a remote condenser rated 80 tons at 50°F, against the 72.4 tons Drake publishes for this unit at 55°F leaving fluid and 95°F ambient on R407C. Drake's table has no 50°F row for this unit, so its 55°F figure is used; a chiller makes at least as much at a warmer set point, so the pick keeps a margin at 50°F. It is refrigeration only with a remote condenser, and works with a pump-tank station.

Product Overview

Part Number:
ES800D
Manufacturer:
Drake
Replacement Unit:
Temptek MA-80-RC-CC

Published Capacity

Cooling Capacity:
72.4 tons at 55°F leaving fluid
Rating Point Used:
55°F leaving fluid, 95°F ambient, R407C
Capacity at 20°F Leaving Fluid:
32.9 tons
Capacity at 35°F Leaving Fluid:
47.5 tons
Capacity at 45°F Leaving Fluid:
59.3 tons
Capacity at 65°F Leaving Fluid:
86.6 tons
R404A Low-Temperature Range:
28 tons at 0°F to 79.4 tons at 55°F
R407C Suction Range:
10°F to 55°F
R404A Suction Range:
-10°F to 45°F

Configuration & Specifications

Horsepower:
80 HP
Compressor:
Semi-Hermetic
Circuits:
Dual
Condenser:
Remote Air-Cooled (split system)
Refrigerant:
R407C or R404A
Condenser Section:
CS800D

Electrical

Voltage Options:
208-230 V three-phase / 460 V three-phase / 575 V three-phase
Frequency:
60 Hz

Dimensions & Weight

Evaporator Section (L x W x H):
110 x 34 x 77 in max
Evaporator Section Weight:
2,400 lbs

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales