1-805-484-2992

Quotes - Sizing - Sales
Replacement unit for the Drake ES Split-System Semi-Hermetic Series

ES Split-System Semi-Hermetic Series

Semi-hermetic compressors indoors, condensers outdoors: Drake's ES semi-hermetic split systems, 10 to 100 hp, for colder duty.

PRODUCT TYPE CAPACITY MODELS
Semi-Hermetic Split Chiller Split-System Air-Cooled 10 to 100 HP 23

Specifications


Configuration & Size

Horsepower:
10 to 100 hp
Models:
23 part numbers
Capacity:
10.6 to 72.4 tons at 55°F
Condenser:
Remote, air-cooled
Refrigerant:
R407C, R404A

Construction

  • Semi-hermetic compressors
  • Indoor evaporator section
  • Outdoor condenser section
  • Single or dual circuit
  • NEMA 3R electrical

Ratings

  • Tables from 20 to 65°F leaving
  • 95°F ambient column used
  • R407C or R404A
  • Refrigerant lines field-run

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

ES Semi-Hermetic Split-System Chillers, 10 to 100 HP

Low-Temperature Split Systems

Twenty-three models, single or dual circuit. Single-circuit ES100S to ES700S and dual-circuit ES150D to ES1000D units on semi-hermetic compressors, with outdoor condenser sections.

The model names overlap the scroll line. Drake uses ES120S, ES250S, ES240D and ES500D for both a scroll and a semi-hermetic split system; the semi-hermetic pages carry "Semi-Hermetic" in their addresses to keep them apart.

Tables run from 20 to 65°F. The ES100S sheet lists 5.5 tons at 20°F up to 12 tons at 65°F leaving fluid in a 95°F ambient on R407C. Drake's R404A sheets go colder, but anything under about 20°F leaving fluid is outside the Temptek line's range and is quoted only after a separate rating.

Two sheets are missing. The ES200S link opens the ES150S sheet and the ES1000D link does not open, so those pages name no replacement.



white milk bottles with blue caps on a green conveyor in a dairy

Semi-hermetic compressors indoors for low-temperature glycol, with the condenser heat rejected outside.

Request a Quote

ES Split-System Semi-Hermetic Series Applications

Low-temperature glycol
Low-temperature glycol
Cold storage
Cold storage
Rooftop condensers
Rooftop condensers
Food processing
Food processing

schematic of the ES Split-System Semi-Hermetic series circuit, showing where the process fluid and the condenser heat go

Low Temperature and Long Lines

A low-temperature split system combines the two things that most change a selection: a cold set point, where capacity falls steeply, and a refrigerant line run, where length and lift cost capacity and oil return. Both have to be known before a replacement is priced.

The glycol type and mix guide covers the glycol side.

Every part-number page below names the Temptek unit we supply in its place, matched at 50°F leaving fluid and 95°F ambient: a Temptek CG-ARC remote-condenser unit or an MA chilling module. For a colder set point we select at your temperature.
Call and talk it through with an engineer: 1-805-484-2992

Before You Replace a Drake ES Semi-Hermetic Split

Look at the compressor itself: a semi-hermetic compressor has a bolted cast body with removable heads, while a scroll is a sealed, welded shell, and the model number on the compressor label settles it. That matters because four ES names, the ES120S, ES250S, ES240D and ES500D, each cover two different machines with two different capacity sheets. The duty is a second clue. The semi-hermetic sheets are built for colder work, with tables starting at 20°F leaving fluid, so a unit that has been holding glycol in the 20s is most likely the semi-hermetic version. Send a photo of the compressor label with the unit nameplate.

Roughly half: the ES150D falls from 18.2 tons at 55°F to 9.2 tons at 20°F, at 95°F ambient on R407C, keeping about 51%. The larger ES800D keeps only about 45%, 32.9 of its 72.4 tons. A ratio borrowed from a small unit will flatter a large one, so a process in the 20s is selected at its own set point and glycol mix.

No: the ES1000D has no published table to work from, because Drake's link to its sheet does not open, and capacity does not scale cleanly with the model number. These sheets show the curve changing shape with size, the larger units giving up a bigger share of their rating at cold set points than the small ones, so a straight-line guess from the ES800D's 72.4 tons at 55°F would be least reliable at the cold set points the series exists for. The ES200S is in the same position, since its link opens the ES150S sheet. For either one, send the nameplate, set point, glycol mix and measured load, and an application specialist selects from those.

About 19% on the ES400D and 5% on the ES500D, measured against Drake's 55°F figures. The ES400D is published at 30.8 tons and the CG-40A-RC we supply is rated 36.7 tons at 50°F, 5.9 tons more; the ES500D is published at 44.2 tons and the MA-50-RC-C at 46.4, only 2.2 tons more. A thin margin is fine at the rating point, but on a low-temperature split system it can vanish once the set point drops or the line run is long. If the ES500D actually runs in the 20s, the selection is redone at that temperature with the line route entered. The MA is refrigeration only, so plan a pump-tank station with it.

As a seperate low-temperature selection, not as a variant of the 50°F match on the part-number page. Drake's R404A tables for these units reach 0°F, where the ES150D is listed at 6.3 tons, about a third of its 18.2-ton R407C figure at 55°F. A unit picked to cover the warm rating would leave that process badly short. Send the set point, the glycol type and concentration, the load and the refrigerant line route. An application specialist confirms what can hold that duty before anything is quoted, and tells you plainly if it sits outside what we supply.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales