1-805-484-2992

Quotes - Sizing - Sales

PAC800D-T

Drake
Product Type Capacity Refrigerant
Packaged Chiller Air-Cooled Packaged 70.5 Tons @ 55°F R407C or R404A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PAC800D-T as shown on this page.

Replacement chiller for the Drake PAC800D-T

Description

The Drake PAC800D-T is an 80 hp dual-circuit screw packaged air-cooled chiller, from the PAC Screw line. Drake publishes a capacity table for it rather than a single rating: 70.5 tons at 55°F leaving fluid and 95°F ambient on R407C, at an EER of 12.9. The same column runs from 34.1 tons at 20°F to 83.1 tons at 65°F. It is offered on R407C for a 10°F to 55°F suction range and R404A for a -10°F to 45°F suction range. Drake lists two RC2-100B compressors of 460 hp each. Replacement: we supply the Temptek TTI-80A, an air-cooled central chiller rated 80 tons at 50°F, against the 70.5 tons Drake publishes for this unit at 55°F leaving fluid and 95°F ambient on R407C. Drake's table has no 50°F row for this unit, so its 55°F figure is used; a chiller makes at least as much at a warmer set point, so the pick keeps a margin at 50°F.

Product Overview

Part Number:
PAC800D-T
Manufacturer:
Drake
Replacement Unit:
Temptek TTI-80A

Published Capacity

Cooling Capacity:
70.5 tons at 55°F leaving fluid
Rating Point Used:
55°F leaving fluid, 95°F ambient, R407C
Capacity at 20°F Leaving Fluid:
34.1 tons
Capacity at 35°F Leaving Fluid:
48.4 tons
Capacity at 45°F Leaving Fluid:
58.9 tons
Capacity at 65°F Leaving Fluid:
83.1 tons
R404A Low-Temperature Range:
27.9 tons at 0°F to 80.5 tons at 55°F
R407C Suction Range:
10°F to 55°F
R404A Suction Range:
-10°F to 45°F

Configuration & Specifications

Horsepower:
80 HP
Compressor:
Screw
Compressor Model:
2 x RC2-100B, 460 hp each
Circuits:
Dual
Condenser:
Air-Cooled
Refrigerant:
R407C or R404A

Electrical

Voltage Options:
208-230 V three-phase / 460 V three-phase / 575 V three-phase
Frequency:
60 Hz

Dimensions & Weight

Dimensions (L x W x H):
175 x 88 x 88 in
Weight:
4,400 lbs

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales