Replacement unit for the Drake PAC Screw Series

PAC Screw Series

The top of Drake's packaged air-cooled range: two screw compressors on dual circuits, 80 to 200 hp, with stepped capacity control from 25 to 100%.

PRODUCT TYPE CAPACITY MODELS
Packaged Chiller Air-Cooled Packaged 80 to 200 HP 7

Specifications


Configuration & Size

Horsepower:
80 to 200 hp
Models:
7 part numbers
Capacity:
70.5 to 214 tons at 55°F
Circuits:
Dual
Refrigerant:
R407C, R404A

Construction

  • Two screw compressors
  • Stepped capacity 25 to 100%
  • Electronic expansion valves
  • Compressor vibration eliminators
  • NEMA 3R electrical

Ratings

  • Tables from 20 to 65°F leaving
  • 70 to 105°F ambient columns
  • R407C or R404A
  • Power: 208-230, 460, 575 V

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

PAC Screw Packaged Air-Cooled Chillers, 80 to 200 HP

Two Screws, Two Circuits

Seven models. The PAC800D-T to PAC2000D-T carry two screw compressors on independent circuits, with electronic expansion valves, compressor vibration eliminators and stepped capacity control from 25 to 100%.

Capacity is tabulated from 20 to 65°F. The PAC1200D-T sheet lists 58.7 tons at 20°F up to 143 tons at 65°F leaving fluid in a 95°F ambient on R407C, and 48 to 139 tons from 0 to 55°F on R404A.

They are large. The PAC1200D-T is listed at 230 x 88 x 81 inches and 6,000 lb, on 208-230, 460 or 575 V three-phase.

One sheet is shared. Drake's product page links the PAC1000D-T to the PAC800D-T sheet, so the PAC1000D-T page shows no figures and names no replacement.



pump room with white-insulated pumps, red valve handles and gauges

Dual screw compressors, dual circuits and stepped capacity, for a whole-plant air-cooled chiller.

Request a Quote

PAC Screw Series Applications

Plant chilled water
Plant chilled water
Dual-circuit redundancy
Dual-circuit redundancy
Outdoor pad installs
Outdoor pad installs
Low-temperature glycol
Low-temperature glycol

schematic of the PAC Screw series circuit, showing where the process fluid and the condenser heat go

At This Size the Loop Is the Plant

A 100-ton-class air-cooled screw chiller serves a header, not a machine, and the rest of the system matters as much as the chiller: the pump arrangement, the tank or buffer volume, and whether one unit or two carry the load. With two circuits, the plant keeps half it's capacity if one trips, and a replacement should keep that.

The tonnage and capacity guide covers how to count the load across the plant.

Every part-number page below names the Temptek unit we supply in its place, matched at 50°F leaving fluid and 95°F ambient: a Temptek TTI air-cooled central chiller to 180 tons, and above that the add-on module range on our sister site.
Call and talk it through with an engineer: 1-805-484-2992

Drake PAC Screw Chillers: What Carries Over

It means the chiller cannot run below about a quarter of its capacity at the operating point without cycling, so a plant whose night or weekend load falls under that step will see the screws start and stop. On a PAC1200D-T, published at 143 tons with 65°F leaving fluid and 95°F air, the first step is roughly 36 tons; at a 20°F set point, where the sheet lists 58.7 tons, it is nearer 15. If the overnight load is a 10-ton cleaning loop, the machine short cycles and leans on the tank to smooth it out. Give us the minimum load as well as the peak, since it decides the buffer volume and whether one large chiller or two smaller ones should carry the header.

TTI air-cooled central chillers cover the PAC800D-T to PAC1600D-T, and the two largest sizes are covered by add-on chiller modules. Model by model: the PAC800D-T, published at 70.5 tons at 55°F, takes the TTI-80A; the PAC1200D-T takes the TTI-150A, rated 135 tons at 50°F; and the PAC1400D-T and PAC1600D-T both take the TTI-180A. The PAC1800D-T and PAC2000D-T are published at 181.1 and 214.4 tons, roughly 2.2 and 2.6 million BTU/hr, past any single Temptek unit, so modules are paired to the measured load. The PAC1000D-T is the gap: with no sheet of its own, it is sized from the nameplate and the load rather than by guessing between the 80 and 120 hp sheets.

A crane and a clear path: the PAC1200D-T measures about 19 feet by 7-1/3 feet and weighs 6,000 lb. The usual surprise is the new unit going in, past fences, pad edges and overhead lines built around the old one. Send the pad size, crane access and supply voltage, and ask for the replacement's footprint and weight with the quote.