1-805-484-2992

Quotes - Sizing - Sales

PAC380S

Drake
Product Type Capacity Refrigerant
Packaged Chiller Air-Cooled Packaged 29.2 Tons @ 55°F R407C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PAC380S as shown on this page.

Replacement chiller for the Drake PAC380S

Description

The Drake PAC380S is a 30 hp single-circuit scroll packaged air-cooled chiller, from the PAC / PACT Scroll line. Drake publishes a capacity table for it rather than a single rating: 29.2 tons at 55°F leaving fluid and 95°F ambient on R407C, at an EER of 10.5. The same column runs from 19.8 tons at 35°F to 34.4 tons at 65°F. Drake lists one ZR380KCE compressor of 30 hp. Replacement: we supply the Temptek TTI-40A, an air-cooled central chiller rated 40 tons at 50°F, against the 29.2 tons Drake publishes for this unit at 55°F leaving fluid and 95°F ambient on R407C. Drake's table has no 50°F row for this unit, so its 55°F figure is used; a chiller makes at least as much at a warmer set point, so the pick keeps a margin at 50°F. It is a central chiller rather than a portable, because the largest Temptek air-cooled portable, the CG-30A (29 tons), falls short of this figure.

Product Overview

Part Number:
PAC380S
Manufacturer:
Drake
Replacement Unit:
Temptek TTI-40A

Published Capacity

Cooling Capacity:
29.2 tons at 55°F leaving fluid
Rating Point Used:
55°F leaving fluid, 95°F ambient, R407C
Capacity at 35°F Leaving Fluid:
19.8 tons
Capacity at 45°F Leaving Fluid:
24.3 tons
Capacity at 65°F Leaving Fluid:
34.4 tons
R407C Suction Range:
25°F to 55°F

Configuration & Specifications

Horsepower:
30 HP
Compressor:
Scroll
Compressor Model:
1 x ZR380KCE
Circuits:
Single
Condenser:
Air-Cooled
Refrigerant:
R407C

Electrical

Voltage Options:
208-230 V three-phase / 460 V three-phase / 575 V three-phase
Frequency:
60 Hz

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales