Description

The Drake PACT12S is a 1.5 hp single-circuit scroll packaged air-cooled chiller with a tank, from the PAC / PACT Scroll line. Drake publishes a capacity table for it rather than a single rating: 1.3 tons at 50°F leaving fluid and 95°F ambient on R407C, at an EER of 7.4. The same column runs from 1 ton at 40°F to 1.8 tons at 70°F. It is offered on R407C for a 25°F to 55°F suction range and R404A for a -10°F to 45°F suction range. Drake lists one ZS11KAE compressor of 3.3 hp. Its tank holds 30 gallons. Replacement: we supply the Temptek CF-1.5A, a fractional-ton portable chiller rated 1.5 tons at 50°F, against the 1.3 tons Drake publishes for this unit at 50°F leaving fluid and 95°F ambient on R407C. Temptek rates at the same 50°F leaving fluid, so the comparison is like for like.

Product Overview

Part Number:
PACT12S
Manufacturer:
Drake
Replacement Unit:
Temptek CF-1.5A

Published Capacity

Cooling Capacity:
1.3 tons at 50°F leaving fluid
Rating Point Used:
50°F leaving fluid, 95°F ambient, R407C
Capacity at 40°F Leaving Fluid:
1 tons
Capacity at 60°F Leaving Fluid:
1.5 tons
Capacity at 70°F Leaving Fluid:
1.8 tons
R404A Low-Temperature Range:
0.6 tons at 5°F to 1.6 tons at 60°F
R407C Suction Range:
25°F to 55°F
R404A Suction Range:
-10°F to 45°F

Configuration & Specifications

Horsepower:
1.5 HP
Compressor:
Scroll
Compressor Model:
1 x ZS11KAE
Circuits:
Single
Condenser:
Air-Cooled
Tank:
Integral tank
Refrigerant:
R407C or R404A

Pump & Reservoir

  • Tank Capacity: 30 gallons

Electrical

  • Voltage Options: 208-230 V single-phase
  • Frequency: 60 Hz

Connections

Process Connections:
3/4 in F-NPT

Dimensions & Weight

Dimensions (L x W x H):
34 x 38 (max) x 60 in
Weight:
550 lbs

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.