1-805-484-2992

Quotes - Sizing - Sales

PWC500D

Drake
Product Type Capacity Refrigerant
Packaged Chiller Water-Cooled Packaged 42.4 Tons @ 50°F R407C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PWC500D as shown on this page.

Replacement chiller for the Drake PWC500D

Description

The Drake PWC500D is a 40 hp dual-circuit scroll packaged water-cooled chiller, from the PWC / PWCT Scroll line. Drake publishes a capacity table for it rather than a single rating: 42.4 tons at 50°F leaving fluid and 105°F condensing temperature on R407C, at an EER of 15.9. The same column runs from 30.8 tons at 35°F to 57.6 tons at 65°F. Drake lists two ZR250KCE compressors of 20 hp each. Replacement: we supply the Temptek TTI-50W, a water-cooled central chiller rated 50 tons at 50°F, against the 42.4 tons Drake publishes for this unit at 50°F leaving fluid and 105°F condensing temperature on R407C. Drake rates this water-cooled table by condensing temperature rather than water temperature; the 105°F column is the usual condensing point on 85°F tower water, and we confirm it with your water temperature. It is a central chiller rather than a portable, because the largest Temptek water-cooled portable, the CG-40W (40 tons), falls short of this figure.

Product Overview

Part Number:
PWC500D
Manufacturer:
Drake
Replacement Unit:
Temptek TTI-50W

Published Capacity

Cooling Capacity:
42.4 tons at 50°F leaving fluid
Rating Point Used:
50°F leaving fluid, 105°F condensing temperature, R407C
Capacity at 35°F Leaving Fluid:
30.8 tons
Capacity at 40°F Leaving Fluid:
34.3 tons
Capacity at 60°F Leaving Fluid:
52.2 tons
Capacity at 65°F Leaving Fluid:
57.6 tons
R407C Suction Range:
25°F to 55°F

Configuration & Specifications

Horsepower:
40 HP
Compressor:
Scroll
Compressor Model:
2 x ZR250KCE, 20 hp each
Circuits:
Dual
Condenser:
Water-Cooled
Refrigerant:
R407C

Electrical

Voltage Options:
208-230 V three-phase / 460 V three-phase / 575 V three-phase
Frequency:
60 Hz

Connections

Process Connections:
3 in F-NPT

Dimensions & Weight

Dimensions (L x W x H):
85 x 34 x 77 in max
Weight:
3,300 lbs

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.