1-805-484-2992

Quotes - Sizing - Sales

PWC90S

Drake
Product Type Capacity Refrigerant
Packaged Chiller Water-Cooled Packaged 10 Tons @ 50°F R407C or R404A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PWC90S as shown on this page.

Replacement chiller for the Drake PWC90S

Description

The Drake PWC90S is a 10 hp single-circuit scroll packaged water-cooled chiller, from the PWC / PWCT Scroll line. Drake publishes a capacity table for it rather than a single rating: 10 tons at 50°F leaving fluid and 105°F condensing temperature on R407C, at an EER of 14.9. The same column runs from 7.3 tons at 35°F to 13.5 tons at 65°F. It is offered on R407C for a 25°F to 55°F suction range and R404A for a -10°F to 45°F suction range. Drake lists one ZB76KCE compressor of 10 hp. Replacement: we supply the Temptek CGD-10W, a water-cooled portable chiller rated 10.6 tons at 50°F, against the 10 tons Drake publishes for this unit at 50°F leaving fluid and 105°F condensing temperature on R407C. Drake rates this water-cooled table by condensing temperature rather than water temperature; the 105°F column is the usual condensing point on 85°F tower water, and we confirm it with your water temperature.

Product Overview

Part Number:
PWC90S
Manufacturer:
Drake
Replacement Unit:
Temptek CGD-10W

Published Capacity

Cooling Capacity:
10 tons at 50°F leaving fluid
Rating Point Used:
50°F leaving fluid, 105°F condensing temperature, R407C
Capacity at 35°F Leaving Fluid:
7.3 tons
Capacity at 40°F Leaving Fluid:
8.1 tons
Capacity at 60°F Leaving Fluid:
12.3 tons
Capacity at 65°F Leaving Fluid:
13.5 tons
R404A Low-Temperature Range:
3.9 tons at 0°F to 12 tons at 55°F
R407C Suction Range:
25°F to 55°F
R404A Suction Range:
-10°F to 45°F

Configuration & Specifications

Horsepower:
10 HP
Compressor:
Scroll
Compressor Model:
1 x ZB76KCE
Circuits:
Single
Condenser:
Water-Cooled
Refrigerant:
R407C or R404A

Electrical

Voltage Options:
208-230 V three-phase / 460 V three-phase / 575 V three-phase
Frequency:
60 Hz

Connections

Process Connections:
1-1/4 in F-NPT

Dimensions & Weight

Dimensions (L x W x H):
58 x 28 x 37 in
Weight:
695 lbs

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales