1-805-484-2992

Quotes - Sizing - Sales

PWCT180D

Drake
Product Type Capacity Refrigerant
Packaged Chiller Water-Cooled Packaged 20 Tons @ 55°F R407C or R404A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PWCT180D as shown on this page.

Replacement chiller for the Drake PWCT180D

Description

The Drake PWCT180D is a 20 hp dual-circuit scroll packaged water-cooled chiller with a tank, from the PWC / PWCT Scroll line. Drake publishes a capacity table for it rather than a single rating: 20 tons at 55°F leaving fluid and 105°F condensing temperature on R407C, at an EER of 14.9. The same column runs from 14.6 tons at 40°F to 27 tons at 70°F. It is offered on R407C for a 25°F to 55°F suction range and R404A for a -10°F to 45°F suction range. Drake lists two ZB76KCE compressors of 10 hp each. Its tank holds 135 gallons. Replacement: we supply the Temptek CG-20W, a water-cooled portable chiller rated 20 tons at 50°F, against the 20 tons Drake publishes for this unit at 55°F leaving fluid and 105°F condensing temperature on R407C. Drake's table has no 50°F row for this unit, so its 55°F figure is used; a chiller makes at least as much at a warmer set point, so the pick keeps a margin at 50°F.

Product Overview

Part Number:
PWCT180D
Manufacturer:
Drake
Replacement Unit:
Temptek CG-20W

Published Capacity

Cooling Capacity:
20 tons at 55°F leaving fluid
Rating Point Used:
55°F leaving fluid, 105°F condensing temperature, R407C
Capacity at 40°F Leaving Fluid:
14.6 tons
Capacity at 45°F Leaving Fluid:
16.3 tons
Capacity at 65°F Leaving Fluid:
24.5 tons
Capacity at 70°F Leaving Fluid:
27 tons
R404A Low-Temperature Range:
7.7 tons at 5°F to 23.5 tons at 60°F
R407C Suction Range:
25°F to 55°F
R404A Suction Range:
-10°F to 45°F

Configuration & Specifications

Horsepower:
20 HP
Compressor:
Scroll
Compressor Model:
2 x ZB76KCE, 10 hp each
Circuits:
Dual
Condenser:
Water-Cooled
Tank:
Integral tank
Refrigerant:
R407C or R404A

Pump & Reservoir

  • Tank Capacity: 135 gallons

Electrical

  • Voltage Options: 208-230 V three-phase / 460 V three-phase / 575 V three-phase
  • Frequency: 60 Hz

Connections

Process Connections:
1-1/2 in F-NPT

Dimensions & Weight

Dimensions (L x W x H):
85 x 34 x 64 in
Weight:
2,195 lbs

Specifications sourced from Drake Refrigeration's published product-line pages and per-model specification sheets (drakechillers.com), September 2026. Drake Refrigeration and the model names shown are trademarks of their owner; Copeland is a trademark of its owner; referenced here for cross-reference only. Drake marks its sheets for reference only. Confirm against the unit nameplate before ordering.