1-805-484-2992

Quotes - Sizing - Sales

GD-3T-1HA

G&D Chillers
Product Type Capacity Refrigerant
Process Chiller Outdoor Packaged 3.4 Tons @ 60°F R-410A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n GD-3T-1HA as shown on this page.

Replacement chiller for the G&D GD-3T-1HA

Description

The G&D Chillers GD-3T-1HA is a packaged scroll-compressor process chiller from G&D's Micro Scroll Series. G&D publishes it at 41,000 Btu/h at 60°F leaving fluid (about 3.4 tons), 34,100 at 50°F, 27,800 at 40°F, in a 90°F ambient, on R-410A. It carries a 3-ton scroll compressor, a 30-gallon reservoir and a 0.75 HP process pump delivering 12 GPM at 25 PSI. Replacement: we supply the Temptek CG-3A, an air-cooled portable chiller rated 2.9 tons at 50°F, about 2.3 tons at 40°F on Temptek's published 0.80 multiplier, against the 2.3 tons G&D publishes for this unit at 40°F (its coldest published rating), so it covers every published setpoint. It is an indoor portable, because Temptek's outdoor packaged range starts at 5 tons.

Product Overview

Part Number:
GD-3T-1HA
Manufacturer:
G&D Chillers
Replacement Unit:
Temptek CG-3A

Published Capacity

Capacity at 60°F Leaving Fluid:
41,000 Btu/h (12.0 kW)
Capacity at 50°F Leaving Fluid:
34,100 Btu/h (10.0 kW)
Capacity at 40°F Leaving Fluid:
27,800 Btu/h (8.1 kW)
Rating Basis:
90°F ambient

Configuration & Specifications

Compressor:
3 Ton Scroll
Refrigerant:
R-410A
Condenser:
Air-Cooled Microchannel
Evaporator:
Stainless Steel Brazed Plate
Controls:
Microprocessor w/ Comm.
Housing:
Powder Coated Aluminum
Electrical Enclosure:
NEMA 3R
Sound Level:
66 dBA at 10 ft

Pump & Reservoir

  • Reservoir: 30 Gallons
  • Process Pump: 0.75 HP
  • Process Flow: 12 GPM at 25 PSI
  • Connection Size: 1"

Electrical

  • Voltage: 230V / 460V
  • Phase: Single Phase / Three Phase
  • Full Load Amps: 28 (230V 1-Ph) / 17 (230V 3-Ph) / 10 (460V 3-Ph)
  • Minimum Circuit Ampacity: 33 (230V 1-Ph) / 21 (230V 3-Ph) / 12 (460V 3-Ph)
  • Maximum Overcurrent Protection: 52 (230V 1-Ph) / 33 (230V 3-Ph) / 17 (460V 3-Ph)

Dimensions & Weight

Dimensions (W x L x H):
36" x 53" x 46"
Operating Weight:
900 lbs
Shipping Weight:
800 lbs

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales