PRODUCT TYPE CAPACITY MODELS
Process Chiller Outdoor Packaged 3 to 15 Tons 5

Specifications


Configuration & Size

Capacity:
3 to 15 Tons nominal
Models:
5 part numbers
Compressor:
Scroll
Process Flow:
12 to 65 GPM
Refrigerant:
R-410A

Construction

  • Scroll compressor, one or two circuits
  • Microchannel air-cooled condenser
  • Insulated stainless glycol reservoir
  • Brass ball valves on supply and return
  • Powder-coated aluminum housing

Ratings

  • Rated at 40, 50 and 60°F
  • 90°F ambient
  • Refrigerant R-410A
  • Power: 230/1, 230/3, 460/3 (3T, 5T)

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.

Micro Scroll Chillers, 3 to 15 Tons

For Loads Above 40°F

Five models on scroll compressors. The Micro Scroll line is G&D's small scroll-compressor chiller, one circuit on the 3 to 10-ton units and two on the GD-15T-2HA, each with an insulated stainless reservoir, a glycol pump and a microchannel air-cooled condenser.

The rating points are higher than the glycol lines. G&D publishes the GD-3T-1HA and GD-5T-1HA at 40, 50 and 60°F leaving fluid: 27,800 to 41,000 Btu/h and 50,200 to 71,500 Btu/h respectively, in a 90°F ambient, on R-410A.

The T is tons. Unlike the H units, the number here is nominal tonnage, and at 50°F the two published models land close to it: about 2.8 tons for the 3T and 5 tons for the 5T.

Three sheets are unreadable. G&D's spec sheets for the 7.5, 10 and 15-ton units are published as outlined artwork, so their capacity and electrical tables are not reproduced here; the product-page figures are.



stainless reactor vessels and piping in a chemical processing hall

Scroll compressors, microchannel condensers and a stainless tank, for process water in the 40s and 50s.

Request a Quote

Micro Scroll Series Applications

Distillery condensers
Distillery condensers
Solvent recovery
Solvent recovery
Machine and laser cooling
Machine and laser cooling
Small HVAC loads
Small HVAC loads

schematic of the Micro Scroll series circuit, showing where the process fluid and the condenser heat go

A Warmer Loop, a Different Compressor

Scroll compressors are efficient and quiet at moderate suction temperatures, which is why G&D rates these units at 40 to 60°F rather than at 20 to 40. A distillery condenser, a solvent-recovery condenser or a machine loop running in the 50s is exactly that duty. Pushed to a 20°F glycol setpoint, a scroll unit loses capacity faster than a reciprocating one, and the glycol lines are the better fit.

When comparing a Micro Scroll with another make, compare at the same leaving temperature. The GD-3T-1HA is a 3.4-ton unit at 60°F and a 2.3-ton unit at 40°F. The leaving fluid temperature guide explains how much capacity each degree costs.

Each part-number page below names the Temptek unit we supply in its place, sized from G&D's coldest published figure (40°F) or, where the sheet cannot be read, from the nominal tonnage in the model number.
Call and talk it through with an engineer: 1-805-484-2992

Sizing Questions on the G&D Micro Scroll

The GD-5T-1HA. Ten GPM through a condenser with a 10°F rise is 50,000 Btu/h by the water formula, and G&D publishes the GD-5T-1HA at 60,300 Btu/h at 50°F and 50,200 at 40°F, so it covers the load anywhere in that band. The GD-3T-1HA, at 34,100 Btu/h at 50°F, falls well short. Measure the condenser's real flow and its inlet and outlet temperatures on a full run, not on warm-up, since the heaviest heat comes when the still is at full boil. If the loop sits in the high 50s, the 60°F figures give a little extra headroom.

About a third on 230 V three-phase and over half on 460 V: G&D lists the GD-5T-1HA at 36 full load amps single-phase, 25 on 230 V three-phase and 14 on 460 V. A small distillery that runs the 5-ton unit on single-phase to avoid a service upgrade should check that 36 amps fits the panel alongside the still's own load. For the three larger models, 7.5 to 15 tons, no readable electrical sheet is published, so take those figures off the nameplate.

No, about 4.2 tons: G&D publishes 50,200 Btu/h at 40°F, against 60,300 at 50°F, where the unit lands near its name. That is why its Temptek pick is the TTOACS-5S-CG-1P, rated 5.3 tons at 50°F and about 4.24 tons at 40°F on Temptek's published 0.80 multiplier, just covering G&D's coldest point. The margin is under 2 percent, so a loop that sits at 40°F all summer on a hot site, or drifts colder, deserves a second look before the order. Tell us the real setpoint and the summer ambient.

Not on any published figure: the GD-10T-1HA sheet cannot be read, so the pick was made on nominal tonnage and its 40°F rating is confirmed on request. The Temptek side is known. The TTOACS-10S-CG-1P is rated 10.2 tons at 50°F and makes about 8.2 tons at 40°F on Temptek's 0.80 multiplier. Against a measured 10-ton load at 40°F, used here only as an example, that would leave the loop about 1.8 tons, or 18 percent, short, so a loop running in the 40s should send its setpoint and load before the order. The GD-15T-2HA pick, the TTOACS-20S-CG-1P at 18.9 tons, still makes about 15.1 tons at 40°F, above the nominal 15. Where the G&D nameplate shows a rating point, send that as well.