Ten G&D series, from a half-ton ForgeLine to a 300 HP plant

Contact us

Glycol Chillers Built for the Cellar

Ten G&D series, 74 part numbers, from a half-ton ForgeLine unit to a 300 HP brewery plant. Each one is listed with its published figures and the unit we supply in its place.

G&D Chillers grew up supplying breweries and wineries, and the range still reads that way: packaged, outdoor-rated glycol chillers with a stainless reservoir and a glycol pump on board, rated at 20, 30 and 40°F leaving glycol rather than at a water-chiller rating point. Around that core sit a scroll line for warmer process loads, a modular base-and-expansion system, a portable unit with a built-in heater for harvest work, an ultra-low temperature line for extraction, and the compact ForgeLine industrial units. The figures on these pages are G&D's own, taken from its product pages, spec sheets and brochures.

  • Single Stage and Multi Stage units run from 1.5 to 27 HP, one or two compressors, 1 to 19 tons at 40°F.
  • Vertical Air units run 30 to 300 HP on semi-hermetic compressors, 23 to 181 tons at 40°F.
  • Micro Scroll and Scroll units use scroll compressors for 40 to 60°F process loads, 3 to 200 nominal tons.
  • Modular base units carry an oversized tank with ports for Expansion Modules added later.
  • ForgeLine HT units are compact air-cooled industrial chillers from 0.5 to 6.1 tons.
  • Fire & Ice portables chill and heat, with 6 to 25 kW elements and four quick-connect tank circuits.
  • LSX units use two-stage compressors to hold -30 to -50°F coolant for extraction work.
74
G&D part numbers in ten series
300 HP
largest listed unit, a brewery plant
20°F
glycol setpoint most matches are made at
0.40
Temptek's published multiplier at 20°F
Replacement unit for the G&D Single Stage Series

Single Stage Series:

Outdoor, One Circuit

  • 7 part numbers
  • 1.1 to 9.6 Tons
  • 20 to 65 GPM process pump
Replacement unit for the G&D Multi Stage Series

Multi Stage Series:

Outdoor, Two Circuits

  • 4 part numbers
  • 8.4 to 19 Tons
  • 40 to 150 GPM process pump
Replacement unit for the G&D Vertical Air Series

Vertical Air Series:

Outdoor, Semi-Hermetic

  • 12 part numbers
  • 23 to 181 Tons
  • 150 to 550 GPM process pump
Replacement unit for the G&D Micro Scroll Series

Micro Scroll Series:

Outdoor, Scroll

  • 5 part numbers
  • 3 to 15 Tons
  • 12 to 65 GPM process pump
Replacement unit for the G&D Scroll Series

Scroll Series:

Outdoor, Tandem Scroll

  • 11 part numbers
  • 20 to 200 Tons
  • 65 to 500 GPM process pump
Replacement unit for the G&D Modular Series

Modular Series:

Base Unit, Expandable

  • 4 part numbers
  • 10 to 27 HP
  • 150 to 230 GPM process pump
Replacement unit for the G&D Expansion Module Series

Expansion Module Series:

Add-On Module

  • 8 part numbers
  • 5 to 50 HP
  • No tank or process pump
Replacement unit for the G&D Fire & Ice Portable Series

Fire & Ice Portable Series:

Portable, Heat or Chill

  • 9 part numbers
  • 3 and 7 HP
  • 25 to 40 GPM process pump
Replacement unit for the G&D LSX Ultra-Low Temp Series

LSX Ultra-Low Temp Series:

Ultra-Low Temperature

  • 7 part numbers
  • 7 to 60 HP
  • Coolant to -50°F
Replacement unit for the G&D ForgeLine HT Series

ForgeLine HT Series:

Compact Industrial

  • 7 part numbers
  • 0.5 to 6.1 Tons
  • Outdoor-rated, R-513A

Reading a G&D Part Number

The number before the H is compressor horsepower, not tons. A GD-10H carries a 10 HP compressor and is published at 98,000 Btu/h at 40°F, a little over 8 tons; at 20°F the same unit makes 64,000 Btu/h, just over 5 tons. Reading the model number as tons overstates the unit by about a fifth at 40°F and by almost 90 percent at 20°F.

The suffix counts compressors. On the Vertical Air units -2C, -3C, -4C and -6C give the compressor count, so a GD-30H-2C is two 15 HP compressors and a GD-35H-1C is one 35 HP compressor in the same cabinet. Multi Stage units write it as 5x5H or 7x7H. On the LSX line 1LC and 2LC do the same job, and on the scroll units the trailing -2 or -4 is the number of scroll compressors.

T means tons, and the letters say what kind of unit it is. The scroll units carry a nominal tonnage (GD-20T-2 is a 20-ton unit). MS marks a Modular Series base chiller, EM an Expansion Module with no tank or pump, and CH a Fire & Ice portable, where the number after the slash is the heater in kilowatts: a CH-3/12.5 is the 3 HP chiller with a 12.5 kW element. ForgeLine numbers follow their own pattern: the four digits read as tons times ten, so a GD-0023TFLR is listed at 2.3 tons.

Replacing a G&D Chiller

We do not sell G&D equipment. We supply new Temptek chillers, and every G&D part-number page names the Temptek unit we would put in its place: the same outdoor packaged format wherever Temptek builds one, the smallest size that covers the published G&D capacity, and a link to that unit's own page on this site. The match is made at G&D's coldest published setpoint, usualy 20°F glycol, so the replacement covers the unit at every temperature G&D rates it. Temptek rates its chillers at 50°F and publishes multipliers of 0.80 at 40°F, 0.60 at 30°F and 0.40 at 20°F, so a GD-10H, listed at 64,000 Btu/h (5.3 tons) at 20°F, needs a Temptek rated at least 13.3 tons. At a warm 40°F setpoint that leaves margin in hand; at a crash-cooling setpoint it is what keeps the cellar on schedule.

Three groups do not map one to one. The smallest cellar units have no outdoor Temptek counterpart, so their pages point to an indoor CG portable. Fire & Ice units heat as well as chill, and the Temptek portable does not. The LSX line runs colder than anything in our range, so those pages send you to an application specialist instead of a model. Before quoting we ask for the nameplate model and serial, the setpoint the process actually runs at, the glycol type and mix, and the voltage.
Call and talk it through with an engineer: 1-805-484-2992

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.

Before You Order

plant engineer reviewing a chiller replacement sizing worksheet

REPLACE • SIZING

Replacement Sizing Guide

Size the new unit from the load and the setpoint, not the old model number, and catch the undersized plant before it is copied.

+ Learn More
aging outdoor chiller showing wear on a concrete pad

REPLACE • CONDITION

Signs You Need a New Chiller

Short cycling, rising amps, a tank that will not pull down: the symptoms that say the old unit is near the end.

+ Learn More
repair and replacement cost comparison sheets on a desk

REPLACE • COST

Repair vs Replace

When a compressor or condenser repair still makes sense, and when the money is better spent on a new unit.

+ Learn More