1-805-484-2992

Quotes - Sizing - Sales

GD-20H

G&D Chillers
Product Type Capacity Refrigerant
Glycol Chiller Outdoor Packaged 16.3 Tons @ 40°F R-448A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n GD-20H as shown on this page.

Replacement chiller for the G&D GD-20H

Description

The G&D Chillers GD-20H is a two-compressor packaged glycol chiller from G&D's Multi Stage Series. G&D publishes it at 196,000 Btu/h at 40°F leaving glycol (about 16.3 tons), 160,000 at 30°F, 128,000 at 20°F, in a 90°F ambient, on R-448A. It carries two 10 HP compressors, a 230-gallon reservoir and a 5 HP process pump delivering 150 GPM at 25 PSI. Replacement: we supply the Temptek TTOACS-30D-MZC-2P, an outdoor air-cooled packaged chiller rated 27.7 tons at 50°F, about 11.1 tons at 20°F on Temptek's published 0.40 multiplier, against the 10.7 tons G&D publishes for this unit at 20°F (its coldest published rating), so it covers every published setpoint.

Product Overview

Part Number:
GD-20H
Manufacturer:
G&D Chillers
Replacement Unit:
Temptek TTOACS-30D-MZC-2P

Published Capacity

Capacity at 40°F Leaving Fluid:
196,000 Btu/h (57.4 kW)
Capacity at 30°F Leaving Fluid:
160,000 Btu/h (46.9 kW)
Capacity at 20°F Leaving Fluid:
128,000 Btu/h (37.5 kW)
Rating Basis:
90°F ambient

Configuration & Specifications

Compressor:
10 HP (x2)
Refrigerant:
R-448A
Condenser:
Air-Cooled Microchannel
Evaporator:
Stainless Steel Brazed Plate
Controls:
Microprocessor w/ Comm.
Housing:
Powder Coated Aluminum
Electrical Enclosure:
NEMA 3R
Sound Level:
68 dBA at 10 ft

Pump & Reservoir

  • Reservoir: 230 Gallons
  • Process Pump: 5 HP
  • Chiller Pump: 1.5 HP
  • Process Flow: 150 GPM at 25 PSI
  • Connection Size: 2"

Electrical

  • Voltage: 208-240V / 460-480V
  • Phase: Three Phase
  • Full Load Amps: 97 (208-240V) / 52 (460-480V)
  • Minimum Circuit Ampacity: 106 (208-240V) / 55 (460-480V)
  • Maximum Overcurrent Protection: 140 (208-240V) / 72 (460-480V)

Dimensions & Weight

Dimensions (W x L x H):
48" x 120" x 87"
Operating Weight:
4,450 lbs
Shipping Weight:
2,450 lbs

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales