1-805-484-2992

Quotes - Sizing - Sales

GD-5x5H

G&D Chillers
Product Type Capacity Refrigerant
Glycol Chiller Outdoor Packaged 8.4 Tons @ 40°F R-448A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n GD-5x5H as shown on this page.

Replacement chiller for the G&D GD-5x5H

Description

The G&D Chillers GD-5x5H is a two-compressor packaged glycol chiller from G&D's Multi Stage Series. G&D publishes it at 101,200 Btu/h at 40°F leaving glycol (about 8.4 tons), 82,200 at 30°F, 65,400 at 20°F, in a 90°F ambient, on R-448A. It carries two 5 HP compressors, a 115-gallon reservoir and a 1.5 HP process pump delivering 40 GPM at 25 PSI. Replacement: we supply the Temptek TTOACS-15S-CG-1P, an outdoor air-cooled packaged chiller rated 14.4 tons at 50°F, about 5.8 tons at 20°F on Temptek's published 0.40 multiplier, against the 5.5 tons G&D publishes for this unit at 20°F (its coldest published rating), so it covers every published setpoint.

Product Overview

Part Number:
GD-5x5H
Manufacturer:
G&D Chillers
Replacement Unit:
Temptek TTOACS-15S-CG-1P

Published Capacity

Capacity at 40°F Leaving Fluid:
101,200 Btu/h (29.7 kW)
Capacity at 30°F Leaving Fluid:
82,200 Btu/h (24.1 kW)
Capacity at 20°F Leaving Fluid:
65,400 Btu/h (19.2 kW)
Rating Basis:
90°F ambient

Configuration & Specifications

Compressor:
5 HP (x2)
Refrigerant:
R-448A
Condenser:
Air-Cooled Microchannel
Evaporator:
Stainless Steel Brazed Plate
Controls:
Microprocessor w/ Comm.
Housing:
Powder Coated Aluminum
Electrical Enclosure:
NEMA 3R
Sound Level:
65 dBA at 10 ft

Pump & Reservoir

  • Reservoir: 115 Gallons
  • Process Pump: 1.5 HP
  • Process Flow: 40 GPM at 25 PSI
  • Connection Size: 1.5"

Electrical

  • Voltage: 230V / 460V
  • Phase: Single Phase / Three Phase
  • Full Load Amps: 84 (230V 1-Ph) / 53 (230V 3-Ph) / 28 (460V 3-Ph)
  • Minimum Circuit Ampacity: 92 (230V 1-Ph) / 58 (230V 3-Ph) / 30 (460V 3-Ph)
  • Maximum Overcurrent Protection: 125 (230V 1-Ph) / 78 (230V 3-Ph) / 40 (460V 3-Ph)

Dimensions & Weight

Dimensions (W x L x H):
48" x 89" x 66"
Operating Weight:
2,400 lbs
Shipping Weight:
1,800 lbs

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.