G&D Chillers
Product Type Capacity Refrigerant
Glycol Chiller Outdoor Packaged 1.1 Tons @ 40°F R-448A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n GD-1.5H as shown on this page.

Replacement chiller for the G&D GD-1.5H

Description

The G&D Chillers GD-1.5H is a single-compressor packaged glycol chiller from G&D's Single Stage Series, sold as the Nano Chill. G&D publishes it at 13,500 Btu/h at 40°F leaving glycol (about 1.1 tons), 10,700 at 30°F, 8,300 at 20°F, in a 90°F ambient, on R-448A. It carries a 1.5 HP compressor, an 18-gallon reservoir and a 0.5 HP process pump delivering 20 GPM at 25 PSI. Replacement: we supply the Temptek CG-2A, an air-cooled portable chiller rated 2 tons at 50°F, about 0.8 tons at 20°F on Temptek's published 0.40 multiplier, against the 0.7 tons G&D publishes for this unit at 20°F (its coldest published rating), so it covers every published setpoint. It is an indoor portable, because Temptek's outdoor packaged range starts at 5 tons.

Product Overview

Part Number:
GD-1.5H
Manufacturer:
G&D Chillers
Replacement Unit:
Temptek CG-2A

Published Capacity

Capacity at 40°F Leaving Fluid:
13,500 Btu/h (4.0 kW)
Capacity at 30°F Leaving Fluid:
10,700 Btu/h (3.1 kW)
Capacity at 20°F Leaving Fluid:
8,300 Btu/h (2.4 kW)
Rating Basis:
90°F ambient

Configuration & Specifications

Compressor:
1.5 HP
Refrigerant:
R-448A
Condenser:
Air-Cooled
Evaporator:
Stainless Steel Brazed Plate
Controls:
Single Stage Digital
Housing:
Powder Coated Aluminum
Electrical Enclosure:
NEMA 3R
Sound Level:
60 dBA at 10 ft

Pump & Reservoir

  • Reservoir: 18 Gallons
  • Process Pump: 0.5 HP
  • Process Flow: 20 GPM at 25 PSI
  • Connection Size: 1"

Electrical

  • Voltage: 230V
  • Phase: Single Phase / Three Phase
  • Full Load Amps: 16 (230V 1-Ph) / 10 (230V 3-Ph)
  • Minimum Circuit Ampacity: 18 (230V 1-Ph) / 12 (230V 3-Ph)
  • Maximum Overcurrent Protection: 27 (230V 1-Ph) / 19 (230V 3-Ph)

Dimensions & Weight

Dimensions (W x L x H):
30" x 35" x 42"
Operating Weight:
550 lbs

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.