1-805-484-2992

Quotes - Sizing - Sales

GD-35H-1C

G&D Chillers
Product Type Capacity Refrigerant
Glycol Chiller Outdoor Packaged 23.4 Tons @ 40°F R-454C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n GD-35H-1C as shown on this page.

Replacement chiller for the G&D GD-35H-1C

Description

The G&D Chillers GD-35H-1C is a packaged glycol chiller on semi-hermetic compressors from G&D's Vertical Air Series. G&D publishes it at 280,900 Btu/h at 40°F leaving glycol (about 23.4 tons), 223,300 at 30°F, 173,900 at 20°F, in a 90°F ambient, on R-454C. It carries a 35 HP compressor, a 235-gallon reservoir and a 5 HP process pump delivering 150 GPM at 25 PSI. Replacement: we supply the Temptek TTOACS-40S-CG-1P, an outdoor air-cooled packaged chiller rated 38.4 tons at 50°F, about 15.4 tons at 20°F on Temptek's published 0.40 multiplier, against the 14.5 tons G&D publishes for this unit at 20°F (its coldest published rating), so it covers every published setpoint.

Product Overview

Part Number:
GD-35H-1C
Manufacturer:
G&D Chillers
Replacement Unit:
Temptek TTOACS-40S-CG-1P

Published Capacity

Capacity at 40°F Leaving Fluid:
280,900 Btu/h (82.3 kW)
Capacity at 30°F Leaving Fluid:
223,300 Btu/h (65.4 kW)
Capacity at 20°F Leaving Fluid:
173,900 Btu/h (51.0 kW)
Rating Basis:
10°F temperature difference, 90°F ambient, sea level

Configuration & Specifications

Compressor:
35 HP
Refrigerant:
R-454C
Condenser:
Air-Cooled Vertical Discharge
Evaporator:
Stainless Steel Brazed Plate
Controls:
Microprocessor w/ Comm.
Housing:
Powder Coated Steel
Electrical Enclosure:
NEMA 3R
Sound Level:
75 dBA at 10 ft

Pump & Reservoir

  • Reservoir: 235 Gallons
  • Process Pump: 5 HP
  • Chiller Pump: 1.5 HP
  • Process Flow: 150 GPM at 25 PSI
  • Connection Size: 3"

Electrical

  • Voltage: 208-240V / 460-480V
  • Phase: Three Phase
  • Full Load Amps: 152 (208-240V) / 78 (460-480V)
  • Minimum Circuit Ampacity: 182 (208-240V) / 94 (460-480V)
  • Maximum Overcurrent Protection: 300 (208-240V) / 150 (460-480V)

Dimensions & Weight

Dimensions (W x L x H):
45" x 167" x 108"
Operating Weight:
5,850 lbs
Shipping Weight:
3,750 lbs

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales