G&D's large packaged glycol plants: 30 to 300 HP on semi-hermetic compressors, with vertical-discharge condensers and tanks up to 1,400 gallons.
| PRODUCT | TYPE | CAPACITY | MODELS |
|---|---|---|---|
| Glycol Chiller | Outdoor Packaged | 23 to 181 Tons | 12 |
Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.
Twelve models, one to six semi-hermetic compressors each. The Vertical Air line uses reciprocating compressors with capacity unloading, from a single 35 HP machine on the GD-35H-1C to six 50 HP machines on the GD-300H-6C, all on R-454C.
Capacity at 40°F runs from 272,300 to 2,175,000 Btu/h, about 23 to 181 tons, with a 10°F temperature difference in a 90°F ambient at sea level. At 20°F the range is 176,000 to 1,495,400 Btu/h.
The package includes the plant. A stainless reservoir of 235 to 1,400 gallons, a process pump of 5 to 20 HP delivering 150 to 550 GPM, and a separate chiller pump, all on one frame with a vertical-discharge air-cooled condenser.
Voltage narrows as the units grow. Up to the GD-100H-2C the line is listed on 208-240 V and 460-480 V three-phase; from the GD-140H-4C up, 460-480 V only.
Semi-hermetic compressors, a stainless tank the size of a small room, and a pump sized for the whole cellar.
Request a Quote
The condenser fans blow straight up, which is why G&D calls this the Vertical Air line. Hot air goes above the unit instead of across the site, so two units can sit closer together and closer to a wall without breathing each other's exhaust. Clearance still matters on the coil side, and a unit boxed in by walls on three sides will run above its 90°F rating ambient on a hot afternoon.
At this size the pumps are a real part of the selection. The process pump is sized for the plant loop, the chiller pump for the evaporator, and the reservoir decouples them. When replacing one, check that the new unit's process pump matches the head of the existing header, not just its flow.
Each part-number page below names the Temptek outdoor unit we supply in its place, sized to cover the published capacity at 20°F, the coldest point G&D rates. At that point the GD-200H-4C, GD-240H-6C and GD-300H-6C are beyond the largest Temptek unit, and their pages point to the largest outdoor units on our sister site.