Product Type Capacity Refrigerant
Glycol Chiller Outdoor Packaged 46.3 Tons @ 40°F R-454C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n GD-70H-2C as shown on this page.

Replacement chiller for the G&D GD-70H-2C

Description

The G&D Chillers GD-70H-2C is a packaged glycol chiller on semi-hermetic compressors from G&D's Vertical Air Series. G&D publishes it at 555,600 Btu/h at 40°F leaving glycol (about 46.3 tons), 444,800 at 30°F, 348,600 at 20°F, in a 90°F ambient, on R-454C. It carries two 35 HP compressors, a 465-gallon reservoir and a 7.5 HP process pump delivering 230 GPM at 25 PSI. Replacement: we supply the Temptek TTOACS-80D-MZC-2P, an outdoor air-cooled packaged chiller rated 75.8 tons at 50°F, about 30.3 tons at 20°F on Temptek's published 0.40 multiplier, against the 29.1 tons G&D publishes for this unit at 20°F (its coldest published rating), so it covers every published setpoint.

Product Overview

Part Number:
GD-70H-2C
Manufacturer:
G&D Chillers
Replacement Unit:
Temptek TTOACS-80D-MZC-2P

Published Capacity

Capacity at 40°F Leaving Fluid:
555,600 Btu/h (162.8 kW)
Capacity at 30°F Leaving Fluid:
444,800 Btu/h (130.4 kW)
Capacity at 20°F Leaving Fluid:
348,600 Btu/h (102.2 kW)
Rating Basis:
10°F temperature difference, 90°F ambient, sea level

Configuration & Specifications

Compressor:
35 HP (x2)
Refrigerant:
R-454C
Condenser:
Air-Cooled Vertical Discharge
Evaporator:
Stainless Steel Brazed Plate
Controls:
Microprocessor w/ Comm.
Housing:
Powder Coated Steel
Electrical Enclosure:
NEMA 3R
Sound Level:
78 dBA at 10 ft

Pump & Reservoir

  • Reservoir: 465 Gallons
  • Process Pump: 7.5 HP
  • Chiller Pump: 2 HP
  • Process Flow: 230 GPM at 25 PSI
  • Connection Size: 3"

Electrical

  • Voltage: 208-240V / 460-480V
  • Phase: Three Phase
  • Full Load Amps: 292 (208-240V) / 156 (460-480V)
  • Minimum Circuit Ampacity: 323 (208-240V) / 172 (460-480V)
  • Maximum Overcurrent Protection: 400 (208-240V) / 225 (460-480V)

Dimensions & Weight

Dimensions (W x L x H):
91" x 113" x 108"
Operating Weight:
10,400 lbs
Shipping Weight:
6,400 lbs

Specifications sourced from G&D Chillers' published product pages, spec sheets and brochures (gdchillers.com), September 2026. G&D Chillers, Nano Chill, Micro Chill and Fire & Ice are trademarks of their owner; referenced here for cross-reference only. Confirm against the unit nameplate before ordering.