1-805-484-2992

Quotes - Sizing - Sales

ICEP060-W

Parker Hannifin
Product Type Capacity Refrigerant
Process Chiller Air-Cooled 16.58 Tons nominal R407C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n ICEP060-W as shown on this page.

Replacement chiller for the Parker Hannifin ICEP060-W

Description

The Parker ICEP060-W is a Hyperchill Plus compact chiller with a non-ferrous hydraulic circuit, a 250-liter tank and a 3 bar pump. Parker lists 58.3 kW, about 16.58 tons, at 20/15°C water and 25°C ambient on R407C. By Parker's correction factors that is about 12.84 tons at 10°C water and 35°C ambient. Replacement: we supply the Temptek CG-15AF, an air-cooled portable chiller rated 14.5 tons at 50°F, against the 12.84 tons Parker Hannifin publishes for this unit at 10°C (50°F) water and 35°C (95°F) ambient. Parker rates the Hyperchill Plus at 15°C water and 25°C ambient and publishes correction factors of 0.87 for 10°C water and 0.89 for 35°C ambient; the figure compared is the nominal capacity times both, which is Temptek's rating point. Parker calls the factors approximate, so we confirm the pick at your set point. The Temptek unit is built for North American 460 V / 60 Hz or 230 V supply, not 50 Hz.

Product Overview

Part Number:
ICEP060-W
Manufacturer:
Parker Hannifin
Replacement Unit:
Temptek CG-15AF

Published Capacity

Nominal Cooling Capacity:
58.3 kW (16.58 tons)
Rating Point:
20/15°C water, 25°C ambient, 0% glycol
At 10°C Water, 35°C Ambient:
12.84 tons (nominal x 0.87 x 0.89, Parker's correction factors)
Operating Limits:
Ambient 5 to 48°C; water outlet 0°C minimum

Configuration & Specifications

Compressor:
1 scroll, 1 circuit
Compressor Absorbed Power:
12.3 kW
SEPR HT:
5.11
Refrigerant:
R407C
Axial Fans:
2
Air Flow:
16,875 m³/h
Sound Pressure at 10 m:
53 dB(A)
Protection Index:
IP54

Pump & Reservoir

  • Pump: P30, 3 bar standard
  • Pump Max Power: 2.2 kW
  • Water Flow (nominal / max): 10.1/18 m³/h
  • Tank Capacity: 250 liters (66 gallons)

Electrical

  • Power Supply: 400 V / 3 ph / 50 Hz

Connections

Water Connections:
1-1/2 in

Dimensions & Weight

Width:
856 mm
Depth:
1956 mm
Height:
1680 mm
Weight (axial fans):
510 kg

Specifications sourced from Parker Hannifin's published Hyperchill bulletins (parker.com), October 2026. Parker, Hiross and Hyperchill are trademarks of their owner; referenced here for cross-reference only. Capacities are Parker's figures at the rating point shown. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales