Parker Hannifin Hyperchill Models

Four Hyperchill lines, from 1.7 kW to 360 kW

Contact us

Parker's Process Chillers Are the Hyperchill Line

Four Hyperchill lines, 42 part numbers, from a 1.7 kW Hyperchill Plus to a 360 kW Hyperchill. Each one is listed with its published capacity and the unit we supply in its place.

Parker Hannifin sells process chillers under the Hyperchill name, from its Gas Separation and Filtration division (the former Hiross business). There are three families: the Hyperchill Plus, a compact chiller with a non-ferrous water circuit; the Hyperchill Plus-E, the same idea on low-GWP R513A; and the larger Hyperchill, a packaged unit with two refrigerant circuits and a tank of up to 1,000 liters. Parker rates the 50 Hz ranges at 20/15°C water and 25°C ambient and the 60 Hz Hyperchill Plus at 55/45°F water and 95°F ambient. The figures on these pages are Parker's own.

  • Hyperchill Plus runs 1.7 to 58.3 kW in twelve 50 Hz sizes.
  • The 60 Hz build covers 4,668 to 65,738 Btu/h in eight sizes.
  • Hyperchill Plus-E runs 2.9 to 120.6 kW on R513A.
  • R513A is in the non-flammable A1 safety class.
  • Hyperchill runs 76 to 360 kW with two or four scroll compressors.
  • Its evaporator sits inside a 400 to 1,000-liter tank.
42
part numbers in four Hyperchill lines
1.7 to 360 kW
Hyperchill Plus up to Hyperchill
77 percent
of nominal at 10°C water and 35°C ambient
R513A
refrigerant on the Plus-E line
Replacement unit for the Parker Hannifin Hyperchill Series

Hyperchill Series:

Packaged, Two Circuits

  • 8 part numbers
  • 76 to 360 kW
  • 400 to 1,000-liter tank
Replacement unit for the Parker Hannifin Hyperchill Plus Series

Hyperchill Plus Series:

Compact, Non-Ferrous

  • 12 part numbers
  • 1.7 to 58.3 kW
  • 15 to 250-liter tank
Replacement unit for the Parker Hannifin Hyperchill Plus 60 Hz Series

Hyperchill Plus 60 Hz Series:

Compact, 60 Hz

  • 8 part numbers
  • 4,668 to 65,738 Btu/h
  • 4 to 26-gallon tank
Replacement unit for the Parker Hannifin Hyperchill Plus-E Series

Hyperchill Plus-E Series:

Compact, R513A

  • 14 part numbers
  • 2.9 to 120.6 kW
  • Non-flammable A1 refrigerant

Reading a Parker Chiller Model

ICE or ICEP. ICE is the Hyperchill; ICEP is the Hyperchill Plus. The digits that follow are a size step close to the nominal kW: an ICE150 lists 149.2 kW, an ICEP024 lists 23.6 kW.

The letter at the end. An E after the digits (ICEP034E) is a Plus-E on R513A. A -W is the water range, as against Parker's oil-cooling version of the same cabinet.

Mind the rating point. Parker's 50 Hz bulletins rate at 15°C leaving water and 25°C ambient, an easy point. The same chiller makes less at 10°C and 35°C: Parker's own factors put it at about 77 percent of nominal. The 60 Hz bulletin rates at 45°F and 95°F instead. The tonnage and capacity guide explains why the rating point matters.

Replacing a Parker Hyperchill

We do not sell Parker Hannifin equiptment. We supply new Temptek chillers, and every Parker part-number page names the Temptek unit we would put in its place. Temptek rates at 50°F leaving fluid and 95°F ambient, so each Parker figure is brought to that point first. For the 50 Hz Hyperchill and Hyperchill Plus we use the correction factors Parker prints in the bulletin for 10°C water and 35°C ambient. For the 60 Hz Hyperchill Plus, rated at 45°F, we use Temptek's published 40°F multiplier of 0.80. The Plus-E bulletin prints no factors, so those picks cover the full nominal figure and carry margin.

A 50 Hz Hyperchill is replaced by a unit for North American supply, so the electrical feed changes with it. Before quoting we ask for the nameplate model and serial, the set point, the glycol mix and the site supply.
Call and talk it through with an engineer: 1-805-484-2992

A note on an older listing: this site once showed an HVP series under Parker. HVP is a Frigel range, and Frigel is not a Parker company, so it is no longer listed here.

Specifications sourced from Parker Hannifin's published Hyperchill bulletins (parker.com), October 2026. Parker, Hiross and Hyperchill are trademarks of their owner; referenced here for cross-reference only. Capacities are Parker's figures at the rating point shown. Confirm against the unit nameplate before ordering.

Before You Order

refrigerant cylinders and gauges for a chiller refrigerant change

REPLACE • REFRIGERANT

Refrigerant Phase-Out

Older units in the field may still run R-22 or R-410A. What the refrigerant change means for service, retrofit and replacement.

+ Learn More
chiller swap-out checklist on a clipboard in a plant room

REPLACE • INSTALL

Swap-Out Checklist

Rigging, electrical, piping and start-up items to settle before the old chiller comes out of service.

+ Learn More
aging outdoor chiller showing wear on a concrete pad

REPLACE • CONDITION

Signs You Need a New Chiller

Short cycling, rising amps, a tank that will not pull down: the symptoms that say the old unit is near the end.

+ Learn More