1-805-484-2992

Quotes - Sizing - Sales

ICE183

Parker Hannifin
Product Type Capacity Refrigerant
Process Chiller Air-Cooled 51.83 Tons nominal R407C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n ICE183 as shown on this page.

Replacement chiller for the Parker Hannifin ICE183

Description

The Parker ICE183 is a Hyperchill packaged process chiller with 4 scroll compressors on two refrigerant circuits, a 1000-liter tank with the evaporator inside it and a 3 bar pump. Parker lists 182.3 kW, about 51.83 tons, at 20/15°C water and 25°C ambient on R407C. By Parker's correction factors that is about 39.67 tons at 10°C water and 35°C ambient. Replacement: we supply the Temptek TTOACS-50S-CG-1P, an outdoor air-cooled packaged chiller rated 42.7 tons at 50°F, against the 39.67 tons Parker Hannifin publishes for this unit at 10°C (50°F) water and 35°C (95°F) ambient. Parker rates the Hyperchill at 15°C water and 25°C ambient and publishes correction factors of 0.86 for 10°C water and 0.89 for 35°C ambient; the figure compared is the nominal capacity times both, which is Temptek's rating point. Parker calls the factors approximate, so we confirm the pick at your set point. The Temptek unit is built for North American 460 V / 60 Hz or 230 V supply, not 50 Hz.

Product Overview

Part Number:
ICE183
Manufacturer:
Parker Hannifin
Replacement Unit:
Temptek TTOACS-50S-CG-1P

Published Capacity

Nominal Cooling Capacity:
182.3 kW (51.83 tons)
Rating Point:
20/15°C water, 25°C ambient, 0% glycol
At 10°C Water, 35°C Ambient:
39.67 tons (nominal x 0.86 x 0.89, Parker's correction factors)
Operating Limits:
Ambient 5 to 45°C; water outlet 0°C minimum

Configuration & Specifications

Compressors / Circuits:
4 hermetic scroll / 2 circuits
Compressor Absorbed Power:
40.1 kW
SEPR HT:
5.04
Refrigerant:
R407C
Axial Fan Air Flow:
46,000 m³/h
Sound Pressure at 10 m:
62 dB(A)
Protection Index:
IP54
Water-Cooled Version:
Offered; condenser water 31.0 m³/h

Pump & Reservoir

  • Pump: P30, 3 bar standard
  • Pump Max Power: 4.5 kW
  • Water Flow (nominal / max): 30/50 m³/h
  • Head (nominal / min): 32/20 m H2O
  • Tank Capacity: 1000 liters (264 gallons)

Electrical

  • Power Supply: 400 V / 3 ph / 50 Hz, no neutral

Connections

Water Connections:
2-1/2 in

Dimensions & Weight

Width:
1287 mm
Depth:
3000 mm
Height:
2298 mm
Weight (axial fans):
1,800 kg

Specifications sourced from Parker Hannifin's published Hyperchill bulletins (parker.com), October 2026. Parker, Hiross and Hyperchill are trademarks of their owner; referenced here for cross-reference only. Capacities are Parker's figures at the rating point shown. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales