Replacement unit for the Parker Hannifin Hyperchill Series

Hyperchill Series

Parker's larger process chiller: the Hyperchill, 76 to 360 kW nominal, with two refrigerant circuits and the evaporator inside the tank.

PRODUCT TYPE CAPACITY MODELS
Process Chiller Packaged, Tank On Board 76 to 360 kW 8

Specifications


Configuration & Size

Capacity:
76 to 360 kW nominal
Models:
8 part numbers
Refrigerant:
R407C
Tank:
400 to 1,000 liters
Supply:
400 V / 3 ph / 50 Hz

Construction

  • Two independent refrigerant circuits
  • Two or four scroll compressors
  • Evaporator inside the water tank
  • 3 bar pump with bypass
  • Axial fans, outdoor rated IP54

Ratings

  • 20/15°C water, 25°C ambient
  • Factor 0.86 at 10°C water
  • Factor 0.89 at 35°C ambient
  • Ambient 5 to 45°C

Specifications sourced from Parker Hannifin's published Hyperchill bulletins (parker.com), October 2026. Parker, Hiross and Hyperchill are trademarks of their owner; referenced here for cross-reference only. Capacities are Parker's figures at the rating point shown. Confirm against the unit nameplate before ordering.

Hyperchill, 76 to 360 kW

Two Circuits and a Big Tank

Eight models. From the ICE076 at 76.0 kW to the ICE360 at 360 kW, at 20/15°C water and 25°C ambient.

Two or four compressors. Two scroll compressors on the ICE076 to ICE116 and four from the ICE150 up, on two independent circuits with automatic rotation.

The evaporator is in the tank. 500 liters on the three smallest, 1,000 liters on the ICE150 to ICE230 and 400 liters on the ICE310 and ICE360.

Versions. Axial fans as standard; centrifugal-fan and water-cooled versions on the ICE076 to ICE230, and a low-water version to -10°C. That version reaches 14°F, colder than any Temptek unit is rated for (about 20°F at the low end), and the picks on these pages assume the standard Hyperchill.



a hard hat and work gloves on a workbench

Two refrigerant circuits, scroll compressors, a tank with the evaporator inside it and a 3 bar pump.

Request a Quote

Hyperchill Series Applications

Plastics molding
Plastics molding
Lasers
Lasers
Chemical process
Chemical process
Outdoor pads
Outdoor pads

schematic of the Hyperchill series circuit, showing where the process fluid and the condenser heat go

Nominal Is Not the Working Capacity

Parker's Hyperchill figure is at 15°C water and 25°C ambient. Its bulletin gives a factor of 0.86 for 10°C water and 0.89 for 35°C ambient, so an ICE150 listed at 149.2 kW makes about 114 kW, 32.5 tons, at Temptek's rating point. The leaving fluid temperature guide explains why set point moves capacity.

Every part-number page below names the Temptek unit we supply in its place, sized from Parker's nominal figure corrected to 10°C water and 35°C ambient with Parker's own published factors.
Call and talk it through with an engineer: 1-805-484-2992

Hyperchill ICE076 to ICE360: Selection Notes

About 49.6 tons, against the 64.83 tons its 228 kW nominal figure works out to. Parker's 0.86 water factor and 0.89 ambient factor multiply to about 0.765, so close to a quarter of the nominal capacity is gone at Temptek's rating point. Parker calls those factors approximate, so for a unit this size we confirm the corrected figure at your actual set point and ambient before selecting. The point cuts both ways: if your loop really runs at 15°C water in a mild room, the old unit may be carrying more than 49.6 tons, and the replacement has to cover that, so send the real conditions. A quick field check helps: measure the evaporator flow and temperature rise on a busy day, multiply 500 by both on water, and compare the result with the corrected figure before deciding which way to size.

Because an ICE076 throws off about 91.4 kW and an ICE360 about 442 kW through its axial fans, and a unit that breathes its own warm discharge loses capacity. Those figures are the nominal cooling plus the compressor power Parker lists, 15.4 kW and 82 kW; fan and pump power add a little more. Two units close together, or one against a wall, recirculate that air on a hot day. The Hyperchill is listed for 5 to 45°C ambient, so a pad that runs hotter than the weather report can push it toward that limit. Send a site sketch with clearances when you ask for the Temptek outdoor unit.

Only if the process relies on it. The ICE150 to ICE230 carry 1,000 liters, double the smallest three, while the ICE310 and ICE360 drop to 400. A batch reactor or cycling press may have been leaning on that stored cold, and less volume shows up as a swing on every cycle. If it matters, a buffer tank goes in alongside the Temptek chiller.

The Temptek TTOACS-30S-CG-1P, an outdoor air-cooled packaged chiller rated 28.8 tons at 50°F, against the 25.14 tons the ICE116 gives once Parker's factors bring it to 10°C water and 35°C air, about 15 percent headroom. At the top of the range, the ICE360 maps to the TTOACS-100D-MZC-2P at 84.6 tons. Two things do not carry over on their own: the 400-volt, 50 Hz three-phase supply, since Temptek supply is North American 460 V or 230 V at 60 Hz, and any special version of the Hyperchill. If the old unit is the water-cooled, centrifugal-fan or low-water version, say so, because the standard pick assumes the axial-fan unit.