Quotes - Sizing - Sales

PB120F5R4CL-A-V

PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 12.33 Tons @ 30°F Not published

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PB120F5R4CL-A-V as shown on this page.

Replacement chiller for the PRO Refrigeration PB120F5R4CL-A-V

Description

The PRO PB120F5R4CL-A-V is a 20 hp packaged glycol chiller from PRO's legacy Classic line, on one 20 hp compressor. PRO's legacy table lists estimated capacity at 90°F ambient: 130,300 Btu/h at 25°F, 148,000 Btu/h at 30°F, 167,500 Btu/h at 35°F leaving fluid. Its circulation pumping is one 2 HP, with one 2 in glycol field connections. Replacement: we supply the Temptek TTOACS-25S-CG-1P, an outdoor air-cooled packaged chiller rated 24.2 tons at 50°F, against the 12.33 tons PRO Refrigeration publishes for this unit at 30°F leaving glycol and 90°F ambient. PRO publishes no 50°F rating. Temptek's published capacity multiplier at a 30°F set point is 0.60 of its 50°F rating, so the pick is sized at PRO's 30°F figure divided by 0.60, and confirmed at your set point before quoting. Divided by 0.60, the 12.33 tons call for at least 20.55 tons of Temptek 50°F rating.

Product Overview

Part Number:
PB120F5R4CL-A-V
Manufacturer:
PRO Refrigeration
Series:
Classic Series
Replacement Unit:
Temptek TTOACS-25S-CG-1P

Published Capacity

Capacity at 25°F, 90°F Ambient:
130,300 Btu/h (10.86 tons)
Capacity at 30°F, 90°F Ambient:
148,000 Btu/h (12.33 tons)
Capacity at 35°F, 90°F Ambient:
167,500 Btu/h (13.96 tons)

Configuration & Specifications

Total Horsepower:
20 HP
Compressors:
1 ea / 20 HP
Frame:
Coated steel
Housing:
Galvanized sheet metal

Pump & Reservoir

  • Circulation Pump: 1 ea 2 HP

Electrical

  • MCA / MOP at 230/3/60: 99/163 A
  • MCA / MOP at 460/3/60: 50/82 A

Connections

Glycol Field Connection:
1 ea 2 in

Dimensions & Weight

Dimensions (L x W x H):
132 x 46 x 87 in
Shipping Weight:
2,800 lbs
Operating Weight:
2,900 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.