Twelve PRO lines, from a 3/4 hp Chill&Flow to a 220 hp Revolution

Contact us

Glycol Chillers for Beverage, Dairy and Food

Twelve PRO Refrigeration lines, current and legacy, 63 part numbers, from a 3/4 hp Chill&Flow to a 220 hp Revolution. Each one is listed with its published capacity and the unit we supply in its place.

PRO Refrigeration builds glycol chillers for breweries, wineries, dairies and food plants, and publishes its range the way those buyers use it: capacity at the glycol temperature, 20, 25, 30 or 35°F, at 90°F ambient, with 100°F figures on most data sheets. Every unit is a packaged air-cooled chiller with its own glycol tank and pumps. The current range runs from the Chill&Flow through ChilStar, MA, the four-circuit PRO4 and the V Piston, with the PROGreen CO2 system above; the legacy V-Scroll, V-Screw, Revolution, Classic, M5 and M45 lines are still in the field. The figures on these pages are PRO's own estimated capacities.

  • Chill&Flow is a 3/4 hp compact unit with dual pumps and a 5-gallon tank.
  • ChilStar and MA run 3 to 13.5 hp on 100 and 200-gallon tanks.
  • PRO4 is one footprint configured from 40 to 100 hp on four circuits.
  • V Piston runs to 2,298,000 Btu/h at 30°F on Bitzer semi-hermetic compressors.
  • PROGreen is a 100 hp CO2 (R744) system with heat recovery.
  • V-Screw and Revolution are legacy screw chillers to 220 hp.
  • V-Scroll and Classic are legacy packaged chillers, 10 to 100 hp.
  • M5 runs down to -5°F; M45 is an ultra-low unit for -45 to -8°F.
63
current and legacy PRO part numbers
3/4 to 220 hp
Chill&Flow up to the Revolution
0.60
Temptek multiplier at a 30°F set point
180°F
heat recovery on the PROGreen line
Replacement unit for the PRO Refrigeration Chill&Flow Series

Chill&Flow Series:

Compact, Dual Pump

  • 1 part number
  • 3/4 HP, 6,430 Btu/h at 35°F
  • 5-gallon tank, casters available
Replacement unit for the PRO Refrigeration ChilStar Series

ChilStar Series:

Packaged, Air-Cooled

  • 4 part numbers
  • 3 to 13.5 HP
  • 100-gallon tank
Replacement unit for the PRO Refrigeration MA Series

MA Series:

Packaged, Dual Pump

  • 6 part numbers
  • 5 to 13.5 HP
  • 100 or 200-gallon tank
Replacement unit for the PRO Refrigeration PRO4 Series

PRO4 Series:

Four Independent Circuits

  • 5 part numbers
  • 40 to 100 HP
  • One 168 x 98 x 94-in footprint
Replacement unit for the PRO Refrigeration V Piston Series

V Piston Series:

Packaged, Semi-Hermetic

  • 19 part numbers
  • Up to 2,586,000 Btu/h
  • 200 to 2,000-gallon tanks
Replacement unit for the PRO Refrigeration PROGreen CO2 Series

PROGreen CO2 Series:

Natural Refrigerant, R744

  • 1 part number
  • 100 HP CO2
  • Heat recovery to 180°F
Replacement unit for the PRO Refrigeration V-Screw Series

V-Screw Series:

Dual Screw, Legacy

  • 3 part numbers
  • 160 to 220 HP
  • 2,000-gallon tank
Replacement unit for the PRO Refrigeration V-Scroll Series

V-Scroll Series:

Dual Scroll, Legacy

  • 2 part numbers
  • 20 and 30 HP
  • 200-gallon tank
Replacement unit for the PRO Refrigeration Revolution Series

Revolution Series:

Dual Screw, Legacy

  • 3 part numbers
  • 160 to 220 HP
  • 2,000-gallon tank
Replacement unit for the PRO Refrigeration Classic Series

Classic Series:

Packaged, Legacy

  • 10 part numbers
  • 10 to 100 HP
  • One or two compressors
Replacement unit for the PRO Refrigeration M5 Series

M5 Series:

Low Temperature, Legacy

  • 7 part numbers
  • 0.75 to 13.5 HP
  • Down to -5°F
Replacement unit for the PRO Refrigeration M45 Series

M45 Series:

Ultra-Low Temperature

  • 2 part numbers
  • 12.2 and 20.2 HP
  • -45 to -8°F

Reading a PRO Part Number

The first letters are the frame family. PE and PM are the smaller ChilStar and MA builds, PB the larger V Piston, V-Screw, Revolution and Classic frames, PS the V-Scroll, M5 and M45 their own legacy lines, and 4B the PRO4. PG is the PROGreen CO2 system.

The digits after it carry compressor count and horsepower. PRO's legacy tables show the pattern: a PB210 is two compressors of 10 hp, a PB250 two of 50 hp, a PS215 two of 15 hp. The figure after R is the tank: R8100 a 100-gallon tank, R81000 a 1,000-gallon tank, R4200 200 gallons on the V-Scroll.

The suffix is the condenser and controls, -A-V on most packaged units and -V-V on the V series, with -VD on the dual-screw machines. The trailing asterisk PRO prints is a placeholder for the voltage and options; it is dropped from the page names here.

Replacing a PRO Chiller

We do not sell PRO Refrigeration equiptment. We supply new Temptek chillers, and every PRO part-number page names the Temptek unit we would put in its place. PRO rates at glycol temperatures and Temptek at 50°F, so the two are joined by Temptek's own published multiplier: at a 30°F set point a Temptek unit makes 0.60 of its 50°F rating, and the pick is PRO's 30°F figure divided by 0.60. That makes the Temptek unit look much larger on paper than the PRO it replaces; at the glycol temperature the two match. Small units map to a Temptek CF or CG portable, the rest to Temptek outdoor packaged chillers, and the largest V Piston and screw machines to the add-on module range on our sister site.

The M45 runs below anything Temptek publishes and names no unit, and one V Piston data sheet lists no capacity. Before quoting we ask for the full nameplate model and serial, the glycol set point and mix, the summer ambient, and the voltage.
Call and talk it through with an engineer: 1-805-484-2992

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

Before You Order

refrigerant cylinders and gauges for a chiller refrigerant change

REPLACE • REFRIGERANT

Refrigerant Phase-Out

Older units in the field may still run R-22 or R-410A. What the refrigerant change means for service, retrofit and replacement.

+ Learn More
chiller swap-out checklist on a clipboard in a plant room

REPLACE • INSTALL

Swap-Out Checklist

Rigging, electrical, piping and start-up items to settle before the old chiller comes out of service.

+ Learn More
aging outdoor chiller showing wear on a concrete pad

REPLACE • CONDITION

Signs You Need a New Chiller

Short cycling, rising amps, a tank that will not pull down: the symptoms that say the old unit is near the end.

+ Learn More