1-805-484-2992

Quotes - Sizing - Sales

M45BT120B86R430-A-V

PRO Refrigeration
Product Type Capacity Refrigerant
Ultra-Low Chiller Ultra-Low Packaged 7.72 Tons @ -20°F R448

Note: Unit pictured is representative of the form factor only and does not depict p/n M45BT120B86R430-A-V as shown on this page.

Representative chiller, not the PRO Refrigeration M45BT120B86R430-A-V

Description

The PRO M45BT120B86R430-A-V is a 20.2 hp ultra-low-temperature chiller from PRO's legacy M45 line, with a stainless coolant reservoir and ultra-low-temp insulation. PRO publishes capacity at 90°F air: 53,400 Btu/h at -45°F, 60,200 Btu/h at -40°F, 75,400 Btu/h at -30°F, 92,700 Btu/h at -20°F, 102,100 Btu/h at -15°F, 116,200 Btu/h at -8°F leaving fluid. It carries a 30-gallon reservoir and a pump rated 60 GPM at 58 ft TDH, on R448. Replacement: PRO rates the M45 at -45 to -8°F leaving fluid, an ultra-low duty Temptek publishes no rating for, so there is no like-for-like unit to name. Talk to an application specialist with the nameplate, the set point and the load.

Product Overview

Part Number:
M45BT120B86R430-A-V
Manufacturer:
PRO Refrigeration
Series:
M45 Series
Replacement Unit:
Application specialist

Published Capacity

Capacity at -45°F, 90°F Air:
53,400 Btu/h (4.45 tons)
Capacity at -40°F, 90°F Air:
60,200 Btu/h (5.02 tons)
Capacity at -30°F, 90°F Air:
75,400 Btu/h (6.28 tons)
Capacity at -20°F, 90°F Air:
92,700 Btu/h (7.72 tons)
Capacity at -15°F, 90°F Air:
102,100 Btu/h (8.51 tons)
Capacity at -8°F, 90°F Air:
116,200 Btu/h (9.68 tons)

Configuration & Specifications

Horsepower:
20.2 HP
Refrigerant:
R448
Condenser Air Flow:
8,400 CFM

Pump & Reservoir

  • Pump: 60 GPM at 58 ft TDH
  • Reservoir: 30 gallons, stainless

Electrical

  • MCA / MOP at 208-230/3: 125/207 A
  • MCA / MOP at 460/3: 57/94 A

Connections

Fluid Connections:
2 in MNPT

Dimensions & Weight

Dimensions (L x W x H):
87 x 57 x 100 in
Shipping Weight:
2,400 lbs
Operating Weight:
2,800 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales