M45 Series

PRO's legacy ultra-low chiller: the M45, rated from -45 to -8°F leaving fluid, with a stainless reservoir.

PRODUCT TYPE CAPACITY MODELS
Ultra-Low Chiller Ultra-Low Temperature 12.2 and 20.2 HP 2

Specifications


Configuration & Size

Capacity:
57,900 and 92,700 Btu/h at -20°F
Models:
2 part numbers
Range:
-45 to -8°F
Pump:
60 GPM at 58 ft
Reservoir:
30 gallons

Construction

  • Ultra-low-temp insulation
  • Stainless coolant reservoir
  • Enhanced pump seals
  • Touchscreen and remote access
  • PROHeat2O heat recovery option

Ratings

  • Rated at -45 to -8°F leaving
  • 90°F air
  • R448 refrigerant
  • 208-230 or 460 V

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

M45 Series, -45 to -8°F

Well Below Glycol Duty

Two models. The M45BT112B70R430-A-V at 12.2 hp and the M45BT120B86R430-A-V at 20.2 hp, in an 87 x 57 x 100-inch frame.

Capacity from -45 to -8°F. At 90°F air, the 20.2 hp unit makes 53,400 Btu/h at -45°F and 116,200 at -8°F.

Built for the cold. Ultra-low-temperature insulation, enhanced pump seals and a 30-gallon stainless reservoir with expansion ports.

Heat recovery available. PROHeat2O onboard heat recovery turns waste heat into hot water.



glycol coolant being poured into a fill port

Ultra-low compressor package, stainless reservoir and a 60 GPM pump.

Request a Quote

M45 Series Applications

Ultra-low duty
Ultra-low duty
Freezing and storage
Freezing and storage
Process cooling
Process cooling
Special fluids
Special fluids

schematic of the M45 series circuit, showing where the process fluid and the condenser heat go

Why These Pages Name No Unit

Temptek publishes nothing at -45 to -8°F, so a tonnage comparison would be a guess. The M45's warmest setpoint is still well under the roughly 20°F where Temptek's range ends. These pages list PRO's figures and send you to an application specialist.
Call and talk it through with an engineer: 1-805-484-2992

PRO M45 Ultra-Low Duty in Practice

A little under half: about 46 percent on the 20.2 hp unit and 45 percent on the 12.2 hp, measured against each model's -8°F figure. In tons, the M45BT120B86R430-A-V falls from 9.68 at -8°F to 4.45 at -45°F, and the M45BT112B70R430-A-V from 6.09 to 2.73. The middle of the range holds up better; at -20°F both still make close to 80 percent of their -8°F output. The trap is a load list built on the warm end while the process actually sits at the cold end, which looks like a unit that pulls down slowly and never quite reaches set point. Quote the temperature you hold, and the one you pull down to if they differ.

A glycol chiller's published rating does not reach this range, and more tons do not buy a colder leaving temperature. The warmest point of the M45's rating, -8°F, already sits below anything Temptek publishes, and the M45 was built for it, down to its insulation and pump seals. We still see requests for a glycol unit with twice the M45's tonnage on the idea that the surplus will cover the cold. It does not, because compressor, controls and fluid handling are chosen for a temperature band, not just a load. An M45 duty goes to an application specialist, who starts from the set point and the fluid.

At full flow the spread is narrow: on a water basis, 60 GPM carries the 20.2 hp unit's 116,200 Btu/h at -8°F across about 3.9°F, and the 12.2 hp unit's 73,100 Btu/h across about 2.4°F. The fluid in an M45 loop is not water. A low-temperature fluid carries less heat per gallon and thickens as it gets colder, so the real spread is wider and the head at 60 GPM climbs above what a water calculation suggests. If the loop has been throttled or extended since installation, the M45 may be delivering well under its rated flow. Record the flow, both loop temperatures, and the fluid with its concentration, along with the 2-inch MNPT connections and the 30-gallon reservoir, so the specialist starts from what the loop actually does.