1-805-484-2992

Quotes - Sizing - Sales

PE105F1R8100-A-V

PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 2.83 Tons @ 30°F R448A/R449A/R454C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PE105F1R8100-A-V as shown on this page.

Replacement chiller for the PRO Refrigeration PE105F1R8100-A-V

Description

The PRO PE105F1R8100-A-V is a packaged air-cooled glycol chiller from PRO Refrigeration's MA line, with a 5 hp compressor rating on the data sheet and a 100-gallon tank. PRO publishes estimated capacity at 90°F ambient: 30,700 Btu/h at 25°F, 33,900 Btu/h at 30°F, 37,400 Btu/h at 35°F leaving glycol. Danfoss Maneurop and Emerson reciprocating and scroll compressors, per PRO's specification. Dual stainless steel centrifugal pump configuration with dedicated process and internal circulation pump. Replacement: we supply the Temptek CGD-5A, an air-cooled portable chiller rated 4.9 tons at 50°F, against the 2.83 tons PRO Refrigeration publishes for this unit at 30°F leaving glycol and 90°F ambient. PRO publishes no 50°F rating. Temptek's published capacity multiplier at a 30°F set point is 0.60 of its 50°F rating, so the pick is sized at PRO's 30°F figure divided by 0.60, and confirmed at your set point before quoting. Divided by 0.60, the 2.83 tons call for at least 4.72 tons of Temptek 50°F rating.

Product Overview

Part Number:
PE105F1R8100-A-V
Manufacturer:
PRO Refrigeration
Series:
MA Series
Replacement Unit:
Temptek CGD-5A

Published Capacity

Capacity at 25°F, 90°F Ambient:
30,700 Btu/h (2.56 tons)
Capacity at 30°F, 90°F Ambient:
33,900 Btu/h (2.83 tons)
Capacity at 35°F, 90°F Ambient:
37,400 Btu/h (3.12 tons)
Capacity at 25°F, 100°F Ambient:
28,600 Btu/h
Capacity at 30°F, 100°F Ambient:
31,700 Btu/h
Capacity at 35°F, 100°F Ambient:
34,900 Btu/h

Configuration & Specifications

Compressor (data sheet):
5 HP
Condenser:
Air Cooled
Refrigerant:
R448A/R449A/R454C
Evaporator:
Brazed Plate
Controls:
Electronic
Electrical Enclosure:
NEMA 4
Sound Level:
76 dB at 1 m

Pump & Reservoir

  • Circulation Pump: 1 HP
  • Process Pump: 1 HP
  • Tank: 100 gallons

Electrical

  • MCA / MOP at 230/1/60: 52 / 80 A
  • MCA / MOP at 230/3/60: 39 / 62 A
  • MCA / MOP at 460/3/60: 19 / 29 A

Connections

Glycol Connections:
2 in
Expansion Fittings:
2 ea 2 in

Dimensions & Weight

Dimensions:
72 inL x 46 inW x 78 inH
Shipping Weight:
1500 lbs
Operating Weight:
2400 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales