1-805-484-2992

Quotes - Sizing - Sales
Replacement unit for the PRO Refrigeration MA Series

MA Series

PRO's MA Series: dual-pump glycol chillers from 5 to 13.5 hp, on a 100-gallon tank or, in the 200 frame, two circuits on 200 gallons.

PRODUCT TYPE CAPACITY MODELS
Glycol Chiller Packaged, Air-Cooled 5 to 13.5 HP 6

Specifications


Configuration & Size

Capacity:
33,900 to 204,600 Btu/h at 30°F
Models:
6 part numbers
Compressor:
5 to 13.5 hp
Pumps:
Process + circulation
Tank:
100 or 200 gallons

Construction

  • Reciprocating and scroll compressors
  • Brazed plate heat exchanger
  • Dedicated process and circulation pumps
  • HDPE insulated tank
  • Coated steel frame

Ratings

  • Rated at 20 to 35°F glycol
  • 90°F and 100°F ambient
  • R448A / R449A / R454C
  • 230 or 460 V

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

MA Series, 5 to 13.5 HP

Process and Circulation Pumps

Six models in two frames. The PE105, PM110 and PM114 run on a 100-gallon tank in a 72 x 46 x 78-inch frame; the PE205, PM210 and PM214 on a 200-gallon tank in a 120 x 50 x 77-inch frame.

Capacity at the glycol temperature. From 33,900 Btu/h at 30°F on the PE105F1R8100 to 204,600 Btu/h on the PM214F6R8200, at 90°F ambient.

Two pumps. A dedicated process pump of 1 to 2 hp and a separate circulation pump, so the tank loop and the process loop run independently.

The 200 frame doubles up. The PE205, PM210 and PM214 roughly double the 100-frame capacity at each horsepower, on a 200-gallon tank.



a plant control room with monitoring screens

Compressors, brazed plate exchanger, process and circulation pumps and an insulated tank on a coated steel frame.

Request a Quote

MA Series Applications

Brewery fermentation
Brewery fermentation
Winery fermentation
Winery fermentation
Dairy processing
Dairy processing
Bakery water
Bakery water

schematic of the MA series circuit, showing where the process fluid and the condenser heat go

Two Pumps, Two Loops

With separate process and circulation pumps, the MA keeps the tank cold whatever the process does, and the process pump can be sized for the plant rather than for the evaporator. When it is replaced, ask how far the process pump pushes; a replacement pump has to match that head. The glycol chiller sizing guide covers the load.

Every part-number page below names the Temptek unit we supply in its place, sized from PRO's 30°F figure on Temptek's published multiplier: a Temptek unit makes 0.60 of its 50°F rating at a 30°F set point, so the pick is the PRO figure divided by 0.60.
Call and talk it through with an engineer: 1-805-484-2992

PRO MA Series: Pump and Frame Questions

The same compressor horsepower comes in both MA frames, and the 200 frame makes roughly twice the capacity at each one. The PM110F3R8100-A-V is listed at 7.03 tons at 30°F and the PM210F6R8200-A-V at 13.89 tons; the first goes to the TTOACS-15S-CG-1P and the second to the TTOACS-25S-CG-1P. At 5 hp the gap is wider still, 2.83 tons on the PE105 against 6.47 on the PE205, which puts one on a CGD-5A portable and the other on a 14.4-ton outdoor unit. Purchase records often carry only the horsepower, and a quote built on that can come out one or two sizes wrong. Read the full part number off the nameplate before requesting a quote.

It goes to the TTOACS-30S-CG-1P, rated 28.8 tons at 50°F. PRO publishes the PM214F6R8200-A-V at 204,600 Btu/h, 17.05 tons, with 30°F glycol in a 90°F ambient; dividing by 0.60 gives 28.42 tons, so the 30S clears the requirement by under 0.4 tons of rating. At 30°F that is roughly 2,800 Btu/h more than the PRO unit. That margin suits a like-for-like swap and is too thin for a winery adding tanks before the next crush, so tell us if the load is growing.

Three of them fall inside the band that one Temptek size covers. The PE205F2R8200-A-V at 6.47 tons, the PM110F3R8100-A-V at 7.03 and the PM114F3R8100-A-V at 8.61, all at 30°F, need 10.78, 11.72 and 14.35 tons of 50°F rating, and the TTOACS-15S-CG-1P is rated 14.4. The fit is uneven: the PE205 has more than three tons of rating to spare, the PM114 has 0.05. Two plants with the same Temptek unit can therefore carry very different reserve, and the PM114 owner is the one to ask about planned growth. The 5 hp PE105F1R8100-A-V, at 33,900 Btu/h, needs 4.71 tons and goes to the CGD-5A portable at 4.9.

Only the two 5 hp models: PRO lists 230 V single-phase on the PE105 and PE205 alongside 230 V and 460 V three-phase, and three-phase only on the rest. That matters because those two map to diffrent Temptek units, the CGD-5A portable for the PE105 and the TTOACS-15S-CG-1P for the PE205. A cellar that ran a PE205 on single-phase service cannot assume the replacement connects to the same supply, so check the voltage and phase of the quoted unit against what is at the disconnect before the order is placed. If three-phase power is available nearby, say so, since it widens the choice.

It can, because PRO's published sound runs from 59 dB at 1 m on the PE205 to 89 dB on the PM210 and PM214. A 30 dB gap between models that share the 200-gallon frame is unusually wide, so read the figure off the data sheet for your own part number before relying on the low end. A PE205 tucked into a cellar beside a tasting room may never have drawn a complaint, and a replacement that is noisier at the same distance can. If the unit sits near offices, a tasting room or neighbors, give us the distance and any limit you have to meet, and the sound data on the unit we supply is compared before the order.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales