1-805-484-2992

Quotes - Sizing - Sales

4B415E400V

PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 38.97 Tons @ 30°F R449A or R454C

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n 4B415E400V as shown on this page.

Replacement chiller for the PRO Refrigeration 4B415E400V

Description

The PRO 4B415E400V is a 60 hp four-circuit packaged glycol chiller from the PRO4 line, one 168 x 98 x 94-inch footprint configured from 40 to 100 hp with independent refrigeration circuits and heat exchangers. PRO publishes capacity on R449A at 90°F ambient (110°F condensing): 354,400 Btu/h at 20°F, 408,000 Btu/h at 25°F, 467,600 Btu/h at 30°F, 533,600 Btu/h at 35°F leaving glycol; R454C figures run lower. It carries a 400-gallon glycol tank and a pump rated 210 GPM at 84 ft TDH. Replacement: we supply the Temptek TTOACS-80D-MZC-2P, an outdoor air-cooled packaged chiller rated 75.8 tons at 50°F, against the 38.97 tons PRO Refrigeration publishes for this unit at 30°F leaving glycol and 90°F ambient on R449A. PRO publishes no 50°F rating. Temptek's published capacity multiplier at a 30°F set point is 0.60 of its 50°F rating, so the pick is sized at PRO's 30°F figure divided by 0.60, and confirmed at your set point before quoting. Divided by 0.60, the 38.97 tons call for at least 64.95 tons of Temptek 50°F rating.

Product Overview

Part Number:
4B415E400V
Manufacturer:
PRO Refrigeration
Series:
PRO4 Series
Replacement Unit:
Temptek TTOACS-80D-MZC-2P

Published Capacity

Capacity at 20°F, 90°F Ambient (R449A):
354,400 Btu/h (29.53 tons)
Capacity at 25°F, 90°F Ambient (R449A):
408,000 Btu/h (34 tons)
Capacity at 30°F, 90°F Ambient (R449A):
467,600 Btu/h (38.97 tons)
Capacity at 35°F, 90°F Ambient (R449A):
533,600 Btu/h (44.47 tons)

Configuration & Specifications

Total Horsepower:
60 HP
Refrigeration Circuits:
Four, independent
Refrigerant:
R449A or R454C
Condenser Air Flow:
44,000 CFM
Sound Level:
82 dB

Pump & Reservoir

  • Pump: 210 GPM at 84 ft TDH
  • Glycol Tank: 400 gallons

Electrical

  • MCA / MOP at 208/3: 334/397 A
  • MCA / MOP at 230/3: 307/363 A
  • MCA / MOP at 460/3: 153/182 A

Connections

Fluid Connections:
3 in MNPT

Dimensions & Weight

Dimensions (L x W x H):
168 x 98 x 94 in
Shipping Weight:
7,000 lbs
Operating Weight:
10,600 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales