1-805-484-2992

Quotes - Sizing - Sales

PB280B130R42000-A-VD

PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 99.42 Tons @ 30°F Not published

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PB280B130R42000-A-VD as shown on this page.

Replacement chiller for the PRO Refrigeration PB280B130R42000-A-VD

Description

The PRO PB280B130R42000-A-VD is a 160 hp screw glycol chiller from PRO's legacy Revolution line, on two compressors of 80 hp each. PRO's legacy table lists estimated capacity at 90°F ambient: 932,000 Btu/h at 20°F, 1,056,000 Btu/h at 25°F, 1,192,999 Btu/h at 30°F, 1,342,000 Btu/h at 35°F leaving fluid. It carries a 2,000-gallon tank with 2 ea 10 HP circulation, 2 ea 15 HP process pumps. Replacement: we supply the Temptek TTOACS-190D-MZC-2P, an outdoor air-cooled packaged chiller rated 170.1 tons at 50°F, against the 99.42 tons PRO Refrigeration publishes for this unit at 30°F leaving glycol and 90°F ambient. PRO publishes no 50°F rating. Temptek's published capacity multiplier at a 30°F set point is 0.60 of its 50°F rating, so the pick is sized at PRO's 30°F figure divided by 0.60, and confirmed at your set point before quoting. Divided by 0.60, the 99.42 tons call for at least 165.7 tons of Temptek 50°F rating.

Product Overview

Part Number:
PB280B130R42000-A-VD
Manufacturer:
PRO Refrigeration
Replacement Unit:
Temptek TTOACS-190D-MZC-2P

Published Capacity

Capacity at 20°F, 90°F Ambient:
932,000 Btu/h (77.67 tons)
Capacity at 25°F, 90°F Ambient:
1,056,000 Btu/h (88 tons)
Capacity at 30°F, 90°F Ambient:
1,192,999 Btu/h (99.42 tons)
Capacity at 35°F, 90°F Ambient:
1,342,000 Btu/h (111.83 tons)

Configuration & Specifications

Total Horsepower:
160 HP
Compressors:
2 ea / 80 HP
Frame:
Coated steel
Housing:
Galvanized sheet metal

Pump & Reservoir

  • Pumps: 2 ea 10 HP circulation, 2 ea 15 HP process
  • Tank: 2,000 gallons

Electrical

  • MCA / MOP at 460/3/60: 432/576 A

Connections

Process Connections:
4 in flange
Expansion Connections:
4 ea 3 in FMPT

Dimensions & Weight

Dimensions (L x W x H):
381 x 102 x 124 in
Shipping Weight:
21,500 lbs
Operating Weight:
41,000 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.