1-805-484-2992

Quotes - Sizing - Sales

PB130B78R8550-V-V

PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 17.92 Tons @ 30°F R448A/R449A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PB130B78R8550-V-V as shown on this page.

Replacement chiller for the PRO Refrigeration PB130B78R8550-V-V

Description

The PRO PB130B78R8550-V-V is a packaged semi-hermetic glycol chiller from PRO Refrigeration's V Piston line, with a 30 hp compressor rating on the data sheet and a 550-gallon tank. PRO publishes estimated capacity at 90°F ambient: 167,100 Btu/h at 20°F, 190,200 Btu/h at 25°F, 215,000 Btu/h at 30°F, 243,000 Btu/h at 35°F leaving glycol. Bitzer semi-hermetic compressors, per PRO's specification. Dual stainless steel centrifugal pump configuration with dedicated process and internal circulation pump. Replacement: we supply the Temptek TTOACS-40S-CG-1P, an outdoor air-cooled packaged chiller rated 38.4 tons at 50°F, against the 17.92 tons PRO Refrigeration publishes for this unit at 30°F leaving glycol and 90°F ambient. PRO publishes no 50°F rating. Temptek's published capacity multiplier at a 30°F set point is 0.60 of its 50°F rating, so the pick is sized at PRO's 30°F figure divided by 0.60, and confirmed at your set point before quoting. Divided by 0.60, the 17.92 tons call for at least 29.87 tons of Temptek 50°F rating.

Product Overview

Part Number:
PB130B78R8550-V-V
Manufacturer:
PRO Refrigeration
Series:
V Piston Series
Replacement Unit:
Temptek TTOACS-40S-CG-1P

Published Capacity

Capacity at 20°F, 90°F Ambient:
167,100 Btu/h (13.93 tons)
Capacity at 25°F, 90°F Ambient:
190,200 Btu/h (15.85 tons)
Capacity at 30°F, 90°F Ambient:
215,000 Btu/h (17.92 tons)
Capacity at 35°F, 90°F Ambient:
243,000 Btu/h (20.25 tons)
Capacity at 20°F, 100°F Ambient:
149,300 Btu/h
Capacity at 25°F, 100°F Ambient:
170,600 Btu/h
Capacity at 30°F, 100°F Ambient:
194,100 Btu/h
Capacity at 35°F, 100°F Ambient:
220,000 Btu/h

Configuration & Specifications

Compressor (data sheet):
30 HP
Condenser:
Air Cooled
Refrigerant:
R448A/R449A
Evaporator:
Brazed Plate
Controls:
Microprocessor
Electrical Enclosure:
NEMA 4
Sound Level:
74 dB at 1 m

Pump & Reservoir

  • Circulation Pump: 7.5 HP
  • Process Pump: 7.5 HP
  • Tank: 550 gallons

Electrical

  • MCA / MOP at 230/3/60: 179 / 282 A
  • MCA / MOP at 460/3/60: 90 / 142 A

Connections

Glycol Connections:
3 in
Expansion Fittings:
2 ea 3 in

Dimensions & Weight

Dimensions:
183 inL x 98 inW x 119 inH
Shipping Weight:
6100 lbs
Operating Weight:
10900 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales