1-805-484-2992

Quotes - Sizing - Sales

PB550B146R82000-V-V

PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 159.58 Tons @ 30°F R448A/R449A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PB550B146R82000-V-V as shown on this page.

Replacement chiller for the PRO Refrigeration PB550B146R82000-V-V

Description

The PRO PB550B146R82000-V-V is a packaged semi-hermetic glycol chiller from PRO Refrigeration's V Piston line, with a 50 hp compressor rating on the data sheet and a 2000-gallon tank. PRO publishes estimated capacity at 90°F ambient: 1,495,000 Btu/h at 20°F, 1,695,000 Btu/h at 25°F, 1,915,000 Btu/h at 30°F, 2,155,000 Btu/h at 35°F leaving glycol. Bitzer semi-hermetic compressors, per PRO's specification. Dual stainless steel centrifugal pump configuration with dedicated process and internal circulation pump. Replacement: no single Temptek unit reaches 265.97 tons, so we supply it from our sister line: add-on chiller modules for plant-wide systems to 300 tons, paired to the load.

Product Overview

Part Number:
PB550B146R82000-V-V
Manufacturer:
PRO Refrigeration
Series:
V Piston Series

Published Capacity

Capacity at 20°F, 90°F Ambient:
1,495,000 Btu/h (124.58 tons)
Capacity at 25°F, 90°F Ambient:
1,695,000 Btu/h (141.25 tons)
Capacity at 30°F, 90°F Ambient:
1,915,000 Btu/h (159.58 tons)
Capacity at 35°F, 90°F Ambient:
2,155,000 Btu/h (179.58 tons)
Capacity at 20°F, 100°F Ambient:
1,340,000 Btu/h
Capacity at 25°F, 100°F Ambient:
1,525,000 Btu/h
Capacity at 30°F, 100°F Ambient:
1,730,000 Btu/h
Capacity at 35°F, 100°F Ambient:
1,950,000 Btu/h

Configuration & Specifications

Compressor (data sheet):
50 HP
Condenser:
Air Cooled
Refrigerant:
R448A/R449A
Evaporator:
Brazed Plate
Controls:
Microprocessor
Electrical Enclosure:
NEMA 4
Sound Level:
87 dB at 1 m

Pump & Reservoir

  • Circulation Pump: 7.5 HP
  • Process Pump: 7.5 HP
  • Tank: 2000 gallons

Electrical

  • MCA / MOP at 230/3/60: 1146 / 1338 A
  • MCA / MOP at 460/3/60: 578 / 674 A

Connections

Glycol Connections:
3 in
Expansion Fittings:
4 ea 3 in

Dimensions & Weight

Dimensions:
417 inL x 98 inW x 119 inH
Shipping Weight:
18700 lbs
Operating Weight:
37000 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales