PRO Refrigeration
Product Type Capacity Refrigerant
Glycol Chiller Air-Cooled Packaged 99.42 Tons @ 30°F R448A/R449A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n PB280B130R42000-V-VD as shown on this page.

Replacement chiller for the PRO Refrigeration PB280B130R42000-V-VD

Description

The PRO PB280B130R42000-V-VD is a screw glycol chiller from PRO Refrigeration's V-Screw line, with a 80 hp compressor rating on the data sheet and a 2000-gallon tank. PRO publishes estimated capacity at 90°F ambient: 932,000 Btu/h at 20°F, 1,056,000 Btu/h at 25°F, 1,192,999 Btu/h at 30°F, 1,342,000 Btu/h at 35°F leaving glycol. Bitzer semi-hermetic screw compressors, per PRO's specification. Dual stainless steel centrifugal pump configuration with dedicated process and internal circulation pump. Replacement: we supply the Temptek TTOACS-190D-MZC-2P, an outdoor air-cooled packaged chiller rated 170.1 tons at 50°F, against the 99.42 tons PRO Refrigeration publishes for this unit at 30°F leaving glycol and 90°F ambient. PRO publishes no 50°F rating. Temptek's published capacity multiplier at a 30°F set point is 0.60 of its 50°F rating, so the pick is sized at PRO's 30°F figure divided by 0.60, and confirmed at your set point before quoting. Divided by 0.60, the 99.42 tons call for at least 165.7 tons of Temptek 50°F rating.

Product Overview

Part Number:
PB280B130R42000-V-VD
Manufacturer:
PRO Refrigeration
Series:
V-Screw Series
Replacement Unit:
Temptek TTOACS-190D-MZC-2P

Published Capacity

Capacity at 20°F, 90°F Ambient:
932,000 Btu/h (77.67 tons)
Capacity at 25°F, 90°F Ambient:
1,056,000 Btu/h (88 tons)
Capacity at 30°F, 90°F Ambient:
1,192,999 Btu/h (99.42 tons)
Capacity at 35°F, 90°F Ambient:
1,342,000 Btu/h (111.83 tons)
Capacity at 25°F, 100°F Ambient:
79,357 Btu/h
Capacity at 30°F, 100°F Ambient:
88,590 Btu/h
Capacity at 35°F, 100°F Ambient:
98,450 Btu/h

Configuration & Specifications

Compressor (data sheet):
80 HP
Condenser:
Air Cooled
Refrigerant:
R448A/R449A
Evaporator:
Brazed Plate
Controls:
Microprocessor
Electrical Enclosure:
NEMA 4
Sound Level:
87 dB at 1 m

Pump & Reservoir

  • Circulation Pump: 10 HP
  • Process Pump: 15 HP
  • Tank: 2000 gallons

Electrical

  • MCA / MOP at 460/3/60: 415 / 559 A

Connections

Glycol Connections:
4 in Flange
Expansion Fittings:
4 ea 3 in

Dimensions & Weight

Dimensions:
387 inL x 98 inW x 119 inH
Shipping Weight:
17000 lbs
Operating Weight:
35000 lbs

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.