Replacement unit for the PRO Refrigeration V-Screw Series

V-Screw Series

PRO's legacy dual-screw chillers: 160 to 220 hp on Bitzer semi-hermetic screws, with a 2,000-gallon tank.

PRODUCT TYPE CAPACITY MODELS
Glycol Chiller Screw, Legacy 160 to 220 HP 3

Specifications


Configuration & Size

Capacity:
1,192,999 to 1,762,000 Btu/h at 30°F
Models:
3 part numbers
Compressors:
2 x 80 to 2 x 110 hp
Pumps:
10 hp circ, 15 hp process
Tank:
2,000 gallons

Construction

  • Bitzer semi-hermetic screw compressors
  • V-coil microchannel condenser
  • Stainless brazed plate evaporator
  • Dual stainless pumps
  • Insulated HDPE tank

Ratings

  • Rated at 20 to 35°F glycol
  • 90°F and 100°F ambient
  • R448A / R449A
  • 460 V three-phase

Specifications sourced from PRO Refrigeration's published chiller data sheets, series one-sheets and legacy specification tables (prochiller.com), October 2026. PRO Refrigeration, PRO Chiller Systems, Chill&Flow, ChilStar, PRO4, V Piston, V-Scroll, Revolution, PROGreen and PROElliot are trademarks of their owner; referenced here for cross-reference only. PRO publishes these as estimated capacities. Confirm against the unit nameplate before ordering.

V-Screw Series, 160 to 220 HP

The Largest Legacy Machines

Three models. The PB280B130R42000-V-VD, PB290B162R42000-V-VD and PB2110B162R42000-V-VD, two screws each of 80, 90 and 110 hp.

Capacity at the glycol temperature. From 1,192,999 Btu/h at 30°F to 1,762,000 Btu/h, at 90°F ambient.

Built like the V Piston. V-coil microchannel condensers, a stainless brazed plate evaporator on electronic expansion valves, and dual stainless pumps of 10 and 15 hp.

A 2,000-gallon tank. HDPE with 3 inches of polyurethane insulation, PVC jacketed, and 4-inch flanged glycol connections.



insulated piping on a building mechanical floor

Two semi-hermetic screws, a V-coil condenser and a 2,000-gallon tank on a structural frame.

Request a Quote

V-Screw Series Applications

Brewery fermentation
Brewery fermentation
Dairy plants
Dairy plants
Cold storage
Cold storage
Plant glycol
Plant glycol

schematic of the V-Screw series circuit, showing where the process fluid and the condenser heat go

Most of These Leave Temptek's Range

Divided by 0.60, two of the three V-Screw figures are beyond any single Temptek unit, and their pages point to the add-on module range on our sister site. The PB280 maps to a Temptek outdoor chiller.

Every part-number page below names the Temptek unit we supply in its place, sized from PRO's 30°F figure on Temptek's published multiplier: a Temptek unit makes 0.60 of its 50°F rating at a 30°F set point, so the pick is the PRO figure divided by 0.60.
Call and talk it through with an engineer: 1-805-484-2992

Legacy V-Screw: Three Things to Check First

No, the match is made on capacity at 30°F glycol, not on compressor type or condenser design. The V-Screw runs two Bitzer semi-hermetic screws on a V-coil microchannel condenser, feeding a stainless brazed plate evaporator through electronic expansion valves. On capacity alone, the PB280B130R42000-V-VD, at 99.42 tons, needs 165.7 tons of 50°F rating and goes to the TTOACS-190D-MZC-2P at 170.1. The 180 and 220 hp models need 193.62 and 244.72 tons, past any single unit, and are covered with add-on modules sized to the plant. The V-Screw sheets list R448A or R449A; confirm which on the nameplate so recovery is arranged ahead of removal.

Possibly, but treat it as a separate decision and settle it before the order rather than after delivery. The tank sits on PRO's structural frame with the 10 hp circulation and 15 hp process pumps and the 4-inch flanged glycol connections, so keeping it means leaving part of the old package in place or re-piping it as a standalone vessel. That is only worth doing if the tank and its insulation are sound; a split PVC jacket, or a tank wall that sweats in summer, says the insulation has taken on water. Tell us wether the plant wants the 2,000-gallon reserve kept, and send photos of the tank and its connections, so the Temptek selection is either piped around it or includes new storage.

Not as published. The PB280 sheet lists 88,590 Btu/h at 30°F in a 100°F ambient against 1,192,999 Btu/h at 90°F, a drop of more than 90 percent for a 10°F rise, which no working chiller shows; it reads like a lost digit or a transcription error. The replacement is therefore sized on the 90°F column. For a site that does see 100°F, work the load from what the plant measures rather than from that column: send the nameplate, the summer set point, and supply and return temperatures logged on a hot afternoon, and the selection is made from those.