1-805-484-2992

Quotes - Sizing - Sales

KSEA060

Thermal Care
Product Type Capacity Refrigerant
Outdoor Chiller Outdoor Packaged 60 Tons @ 50°F R-454B or R-410A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n KSEA060 as shown on this page.

Replacement chiller for the Thermal Care KSEA060

Description

The Thermal Care KSEA060 is a packaged outdoor air-cooled chiller from the Accuchiller KSE Series. Thermal Care publishes it at 60 tons (211 kW) at 50°F leaving coolant, 95°F ambient air, with a 20 to 80°F set point range. It runs two scroll compressors, on two refrigeration circuits, on R-454B or R-410A. The pumps are an option: 10 hp standard-pressure for 144 GPM at 50 PSI, or 15 hp high-pressure at 80 PSI. Replacement: we supply the Temptek TTOACS-80D-MZC-2P, an outdoor air-cooled packaged chiller rated 75.8 tons at 50°F, against the 60 tons Thermal Care publishes for this unit at 50°F. Both makers rate at 50°F leaving fluid, so the comparison is like for like. It is a dual-zone unit, so the two-circuit redundancy carries over.

Product Overview

Part Number:
KSEA060
Manufacturer:
Thermal Care
Replacement Unit:
Temptek TTOACS-80D-MZC-2P

Published Capacity

Cooling Capacity:
60 tons (211 kW)
Rating Basis:
50°F leaving coolant, 95°F ambient air
Set Point Range:
20 to 80°F

Configuration & Specifications

Compressor:
Scroll
Compressors:
2
Refrigeration Circuits:
Two
Refrigerant:
R-454B or R-410A
Condenser:
Air-Cooled Microchannel
Evaporator:
Stainless Steel Brazed Plate
Controls:
PLC, Color Touch Screen

Pump & Reservoir

  • Pump Package, Standard Pressure: 10 hp, 144 GPM at 50 PSI
  • Pump Package, High Pressure: 15 hp at 80 PSI
  • Integral Tank: Optional (KSE with Tank)

Electrical

  • Voltage: 460V
  • Phase: Three Phase
  • Frequency: 60 Hz
  • Minimum Circuit Ampacity: 124 A
  • Maximum Overcurrent Protection: 175 A

Connections

Process Connections:
4 in
Process Connections, High Flow:
4 in

Dimensions & Weight

Dimensions (L x W x H):
173 x 47 x 79 in
Shipping Weight:
3,976 lbs (1,803 kg)
Operating Weight:
4,251 lbs (1,928 kg)

Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales