1-805-484-2992

Quotes - Sizing - Sales

KSEA120

Thermal Care
Product Type Capacity Refrigerant
Outdoor Chiller Outdoor Packaged 120 Tons @ 50°F R-454B or R-410A

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n KSEA120 as shown on this page.

Replacement chiller for the Thermal Care KSEA120

Description

The Thermal Care KSEA120 is a packaged outdoor air-cooled chiller from the Accuchiller KSE Series. Thermal Care publishes it at 120 tons (422 kW) at 50°F leaving coolant, 95°F ambient air, with a 20 to 80°F set point range. It runs four scroll compressors, on two refrigeration circuits, on R-454B or R-410A. The pumps are an option: 15 hp standard-pressure for 288 GPM at 62 PSI, or 25 hp high-pressure at 76 PSI. Replacement: we supply the Temptek TTOACS-150D-MZC-2P, an outdoor air-cooled packaged chiller rated 145.8 tons at 50°F, against the 120 tons Thermal Care publishes for this unit at 50°F. Both makers rate at 50°F leaving fluid, so the comparison is like for like. It is a dual-zone unit, so the two-circuit redundancy carries over.

Product Overview

Part Number:
KSEA120
Manufacturer:
Thermal Care
Replacement Unit:
Temptek TTOACS-150D-MZC-2P

Published Capacity

Cooling Capacity:
120 tons (422 kW)
Rating Basis:
50°F leaving coolant, 95°F ambient air
Set Point Range:
20 to 80°F

Configuration & Specifications

Compressor:
Scroll
Compressors:
4
Refrigeration Circuits:
Two
Refrigerant:
R-454B or R-410A
Condenser:
Air-Cooled Microchannel
Evaporator:
Stainless Steel Brazed Plate
Controls:
PLC, Color Touch Screen

Pump & Reservoir

  • Pump Package, Standard Pressure: 15 hp, 288 GPM at 62 PSI
  • Pump Package, High Pressure: 25 hp at 76 PSI
  • Integral Tank: Optional (KSE with Tank)

Electrical

  • Voltage: 460V
  • Phase: Three Phase
  • Frequency: 60 Hz
  • Minimum Circuit Ampacity: 236 A
  • Maximum Overcurrent Protection: 300 A

Connections

Process Connections:
4 in
Process Connections, High Flow:
6 in

Dimensions & Weight

Dimensions (L x W x H):
173 x 88 x 79 in
Shipping Weight:
5,954 lbs (2,701 kg)
Operating Weight:
6,229 lbs (2,825 kg)

Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Sizing - Sales