TCR300D

Thermal Care
Product Type Capacity Refrigerant
Central Chiller Remote Condenser 70 Tons @ 50°F R-513A or R-134a

Note: Unit pictured is the replacement unit, representative of standard unit, and may not exactly depict p/n TCR300D as shown on this page.

Replacement chiller for the Thermal Care TCR300D

Description

The Thermal Care TCR300D is a centrifugal central chiller with remote air-cooled condensers from the Accuchiller TC Series. Thermal Care publishes it at 70 tons (246 kW) at 50°F set point, 60°F return, 95°F condenser air, one configuration of a frame its series table lists at 30 to 180 tons, with a 40 to 75°F set point range. It runs one Turbocor centrifugal compressor, on R-513A or R-134a. Thermal Care pairs it with the LEVF-16410 remote air-cooled condenser. Replacement: we supply the Temptek MA-70-RC-CC, an air-cooled chilling module with a remote condenser rated 70 tons at 50°F, against the 70 tons Thermal Care publishes for this unit at 50°F. Both makers rate at 50°F leaving fluid, so the comparison is like for like. Like this unit, it carries no tank; it works with a pump-tank station.

Product Overview

Part Number:
TCR300D
Manufacturer:
Thermal Care
Replacement Unit:
Temptek MA-70-RC-CC

Published Capacity

Cooling Capacity:
70 tons (246 kW)
Frame Capacity Range:
30 to 180 tons
Rating Basis:
50°F set point, 60°F return, 95°F condenser air
Set Point Range:
40 to 75°F

Configuration & Specifications

Compressor:
Turbocor Centrifugal, Magnetic Bearing
Compressors:
1
Refrigeration Circuits:
One
Refrigerant:
R-513A or R-134a
Condenser:
Remote Air-Cooled
Evaporator:
Stainless Steel Brazed Plate
Controls:
PLC

Electrical

Voltage:
460V
Phase:
Three Phase
Frequency:
60 Hz
Minimum Circuit Ampacity:
173 A
Maximum Overcurrent Protection:
300 A

Connections

Process Connections:
3 in flange
Refrigerant Discharge Line:
2-1/8 in
Refrigerant Liquid Line:
1-3/8 in
Remote Condenser:
LEVF-16410
Condenser Fans:
6

Dimensions & Weight

Dimensions (L x W x H):
105 x 29 x 77 in
Shipping Weight:
1,900 lbs (862 kg)
Operating Weight:
2,100 lbs (953 kg)

Specifications sourced from Thermal Care's published unit pages and series specification tables (thermalcare.com), September 2026. Thermal Care, Accuchiller and the series names shown are trademarks of their owner; referenced here for cross-reference only. Turbocor is a trademark of its owner. Confirm against the unit nameplate before ordering.